Influence of wilson ce nter terminal on fetal electrocardiography acquisition
Auteur(s) :
Charlier, P. [Auteur]
Logier, Regis [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Cabon, Sarah [Auteur]
Garabedian, Charles [Auteur]
Debarge, V. [Auteur]
De Jonckheere, Julien [Auteur]
Logier, Regis [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Cabon, Sarah [Auteur]
Garabedian, Charles [Auteur]
Debarge, V. [Auteur]
De Jonckheere, Julien [Auteur]
Titre de la revue :
Conference proceedings . ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
Nom court de la revue :
Conf Proc IEEE Eng Med Biol Soc
Numéro :
2018
Pagination :
5545-5548
Date de publication :
2018-07-01
ISSN :
1557-170X
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
The acquisition of a standard 10-leads electrocardiography (ECG) is performed using the Wilson Center Terminal (WCT) reference with a normalized electrode positioning. However, in the case of non-invasive fetal ECG (fECG) ...
Lire la suite >The acquisition of a standard 10-leads electrocardiography (ECG) is performed using the Wilson Center Terminal (WCT) reference with a normalized electrode positioning. However, in the case of non-invasive fetal ECG (fECG) acquisition, there is no standardization on the positioning of the electrodes on the abdomen and many authors suggest an acquisition with or without a WCT. The use of the WCT for the acquisition of the fetal heart rate (FHR) is not justified. The objective of this paper is to quantify the influence of this reference compared to a direct measurement. For this purpose, we developed a device allowing the acquisition of the fECG and compared the two configurations on 6 volunteer pregnants. The noise levels and the fetal QRS morphology were compared, showing no superiority of the WCT acquisition compared to a direct differential measurement.Lire moins >
Lire la suite >The acquisition of a standard 10-leads electrocardiography (ECG) is performed using the Wilson Center Terminal (WCT) reference with a normalized electrode positioning. However, in the case of non-invasive fetal ECG (fECG) acquisition, there is no standardization on the positioning of the electrodes on the abdomen and many authors suggest an acquisition with or without a WCT. The use of the WCT for the acquisition of the fetal heart rate (FHR) is not justified. The objective of this paper is to quantify the influence of this reference compared to a direct measurement. For this purpose, we developed a device allowing the acquisition of the fECG and compared the two configurations on 6 volunteer pregnants. The noise levels and the fetal QRS morphology were compared, showing no superiority of the WCT acquisition compared to a direct differential measurement.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
Université de Lille
Université de Lille
Date de dépôt :
2019-12-09T16:48:33Z