A Method for Actuator Lock-in-place Failure ...
Type de document :
Communication dans un congrès avec actes
Titre :
A Method for Actuator Lock-in-place Failure Detection in Aircraft Control Surface Servo-loops
Auteur(s) :
Cieslak, Jérôme [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Efimov, Denis [Auteur]
Non-Asymptotic estimation for online systems [NON-A]
Zolghadri, Ali [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Gheorghe, Anca [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Goupil, Philippe [Auteur]
Dayre, Rémy [Auteur]
Airbus [France]
Laboratoire de l'intégration, du matériau au système [IMS]
Efimov, Denis [Auteur]
Non-Asymptotic estimation for online systems [NON-A]
Zolghadri, Ali [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Gheorghe, Anca [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Goupil, Philippe [Auteur]
Dayre, Rémy [Auteur]
Airbus [France]
Titre de la manifestation scientifique :
IFAC World Congress'14
Ville :
Cape Town
Pays :
Afrique du Sud
Date de début de la manifestation scientifique :
2014-08-25
Date de publication :
2014-08-25
Discipline(s) HAL :
Informatique [cs]/Automatique
Résumé en anglais : [en]
This paper deals with a signal-based method for robust and early detection of lock-in-place failures (a.k.a. jamming) in aircraft control surface servo-loops. Earlier and robust detection of such failures is an important ...
Lire la suite >This paper deals with a signal-based method for robust and early detection of lock-in-place failures (a.k.a. jamming) in aircraft control surface servo-loops. Earlier and robust detection of such failures is an important issue since they may cause additional structural load and affect the sustainability of civil transport airplane. The proposed signal-based scheme uses a sliding-mode differentiator to provide derivatives of measurable signals in noisy environment. Jamming events are next detected by using a dedicated decision making-rule that is able to detect actuator outage (the stuck value can be near zero). The proposed monitoring scheme has been tested on Airbus test facilities located at Toulouse, France. The results confirm good level of robustness and performance, even in extreme situations. The proposed technique can be applied, with slight modifications, to any type of actuator, e.g. Hydraulic, Electro-Hydrostatic (EHA) or Electro-Backup-Hydrostatic (EBHA) actuators.Lire moins >
Lire la suite >This paper deals with a signal-based method for robust and early detection of lock-in-place failures (a.k.a. jamming) in aircraft control surface servo-loops. Earlier and robust detection of such failures is an important issue since they may cause additional structural load and affect the sustainability of civil transport airplane. The proposed signal-based scheme uses a sliding-mode differentiator to provide derivatives of measurable signals in noisy environment. Jamming events are next detected by using a dedicated decision making-rule that is able to detect actuator outage (the stuck value can be near zero). The proposed monitoring scheme has been tested on Airbus test facilities located at Toulouse, France. The results confirm good level of robustness and performance, even in extreme situations. The proposed technique can be applied, with slight modifications, to any type of actuator, e.g. Hydraulic, Electro-Hydrostatic (EHA) or Electro-Backup-Hydrostatic (EBHA) actuators.Lire moins >