Enhancing prediction stability and performance ...
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
Enhancing prediction stability and performance in LIBS analysis using custom CNN architectures.
Author(s) :
Dehbozorgi, P. [Auteur]
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Motto-Ros, V. [Auteur]
Institut Lumière Matière [Villeurbanne] [ILM]
Bocklitz, T. W. [Auteur]
Friedrich-Schiller-Universität = Friedrich Schiller University Jena [Jena, Germany]
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Motto-Ros, V. [Auteur]
Institut Lumière Matière [Villeurbanne] [ILM]
Bocklitz, T. W. [Auteur]
Friedrich-Schiller-Universität = Friedrich Schiller University Jena [Jena, Germany]
Journal title :
Talanta
Abbreviated title :
Talanta
Volume number :
284
Pages :
127192
Publication date :
2024-12-07
ISSN :
1873-3573
HAL domain(s) :
Chimie/Chimie théorique et/ou physique
English abstract : [en]
LIBS-based analysis has experienced an ever-increasing interest in recent years as a well-suited technique for chemical analysis tasks relying on elemental fingerprinting. This method stands out for its ability to offer ...
Show more >LIBS-based analysis has experienced an ever-increasing interest in recent years as a well-suited technique for chemical analysis tasks relying on elemental fingerprinting. This method stands out for its ability to offer rapid, simultaneous multi-element analysis with the advantage of portability. In the context of this research, our aim is to bridge the gap between the analysis of simulated and real data to better account for variations in plasma temperature and electron density, which are typically not considered in LIBS analysis. To achieve this, we employ two distinct methodologies, PLS and CNNs, to construct predictive models for predicting the concentration of the 24 elements within each LIBS spectrum. The initial phase of our investigation concentrates on the training and testing of these models using simulated LIBS data, with results evaluated through RMSEP values. The IQR and median RMSEP values for all the elements demonstrate that CNNs consistently achieved values below 0.01, while PLS results ranged from 0.01 to 0.05, highlighting the superior stability and predictive accuracy of CNNs model. In the next phase, we applied the pre-trained models to analyze the real LIBS spectra, consistently identifying Aluminum (Al), Iron (Fe), and Silicon (Si) as having the highest predicted concentrations. The overall predicted values were approximately 0.5 for Al, 0.6 for Si, and 0.04 for Fe. In the third phase, deliberate adjustments are made to the training parameters and architecture of the proposed CNNs model to force the network to emphasize specific elements, prioritizing them over other components present in each real LIBS spectrum. The generation of the three modified versions of the initially proposed CNNs allows us to explore the impact of regularization, sample weighting, and a customized loss function on prediction outcomes. Some elements emerge during the prediction phase, with Calcium (Ca), Magnesium (Mg), Zinc (Zn), Titanium (Ti), and Gallium (Ga) exhibiting more pronounced patterns.Show less >
Show more >LIBS-based analysis has experienced an ever-increasing interest in recent years as a well-suited technique for chemical analysis tasks relying on elemental fingerprinting. This method stands out for its ability to offer rapid, simultaneous multi-element analysis with the advantage of portability. In the context of this research, our aim is to bridge the gap between the analysis of simulated and real data to better account for variations in plasma temperature and electron density, which are typically not considered in LIBS analysis. To achieve this, we employ two distinct methodologies, PLS and CNNs, to construct predictive models for predicting the concentration of the 24 elements within each LIBS spectrum. The initial phase of our investigation concentrates on the training and testing of these models using simulated LIBS data, with results evaluated through RMSEP values. The IQR and median RMSEP values for all the elements demonstrate that CNNs consistently achieved values below 0.01, while PLS results ranged from 0.01 to 0.05, highlighting the superior stability and predictive accuracy of CNNs model. In the next phase, we applied the pre-trained models to analyze the real LIBS spectra, consistently identifying Aluminum (Al), Iron (Fe), and Silicon (Si) as having the highest predicted concentrations. The overall predicted values were approximately 0.5 for Al, 0.6 for Si, and 0.04 for Fe. In the third phase, deliberate adjustments are made to the training parameters and architecture of the proposed CNNs model to force the network to emphasize specific elements, prioritizing them over other components present in each real LIBS spectrum. The generation of the three modified versions of the initially proposed CNNs allows us to explore the impact of regularization, sample weighting, and a customized loss function on prediction outcomes. Some elements emerge during the prediction phase, with Calcium (Ca), Magnesium (Mg), Zinc (Zn), Titanium (Ti), and Gallium (Ga) exhibiting more pronounced patterns.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
CNRS
CNRS
Collections :
Research team(s) :
Propriétés magnéto structurales des matériaux (PMSM)
Submission date :
2024-12-09T22:01:48Z
2024-12-18T08:05:16Z
2024-12-18T08:05:16Z