Optimization of brain perfusion image ...
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
Optimization of brain perfusion image quality by cortical surface-based projection of arterial spin labeling maps in early-onset alzheimer's disease patients
Author(s) :
Verclytte, Sébastien [Auteur]
Lopes, Renaud [Auteur]
Delmaire, Christine [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Ferre, Jean-Christophe [Auteur]
Pasquier, Florence [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Leclerc, Xavier [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Lopes, Renaud [Auteur]
Delmaire, Christine [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Ferre, Jean-Christophe [Auteur]
Pasquier, Florence [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Leclerc, Xavier [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Journal title :
European radiology
Abbreviated title :
Eur. Radiol.
Volume number :
25
Pages :
2479-2484
Publication date :
2015-08-01
ISSN :
0938-7994
English keyword(s) :
Early-onset Alzheimer''s disease
Alzheimer''s disease
Perfusion
Cortical surface-based analysis
Arterial spin labelling
Alzheimer''s disease
Perfusion
Cortical surface-based analysis
Arterial spin labelling
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
OBJECTIVE: Arterial spin labelling (ASL) is a promising MRI sequence that allows noninvasive detection of cortical perfusion alterations in neurodegenerative disorders, but its interpretation remains difficult at an ...
Show more >OBJECTIVE: Arterial spin labelling (ASL) is a promising MRI sequence that allows noninvasive detection of cortical perfusion alterations in neurodegenerative disorders, but its interpretation remains difficult at an individual level. In this work, a cortical surface-based projection of ASL maps was applied in patients with early-onset Alzheimer's disease (EOAD) to improve the image quality and visual representation of perfusion data. METHODS: Eighteen patients referred from the reference centre for EOAD were assessed by MRI with ASL sequences. Data processing was applied on each examination including correction of partial volume effects and cortical projection of preprocessed ASL data. Cortical segmentation and perfusion display were qualitatively analyzed according to a three-point scale. RESULTS: All examinations were suitable for complete data processing. Quality of segmentation and of cortical surface-based perfusion maps was scored as optimal in 72 % in both cases. Cortical surface-based ASL maps provided a more global view than single slices and an accurate approach of brain perfusion in EOAD patients. CONCLUSIONS: Cortical surface-based analysis of ASL maps is technically feasible with a good image quality and may enable significant improvement in the detection of focal perfusion alterations in neurodegenerative disorders in the real-life clinical setting. CONCLUSIONS: • Arterial spin labelling is a promising sequence for assessing Alzheimer's disease. • Optimization of ASL brain perfusion image quality is crucial for image interpretation. • Cortical surface-based analysis may improve detection of perfusion alterations in a real-life clinical setting.Show less >
Show more >OBJECTIVE: Arterial spin labelling (ASL) is a promising MRI sequence that allows noninvasive detection of cortical perfusion alterations in neurodegenerative disorders, but its interpretation remains difficult at an individual level. In this work, a cortical surface-based projection of ASL maps was applied in patients with early-onset Alzheimer's disease (EOAD) to improve the image quality and visual representation of perfusion data. METHODS: Eighteen patients referred from the reference centre for EOAD were assessed by MRI with ASL sequences. Data processing was applied on each examination including correction of partial volume effects and cortical projection of preprocessed ASL data. Cortical segmentation and perfusion display were qualitatively analyzed according to a three-point scale. RESULTS: All examinations were suitable for complete data processing. Quality of segmentation and of cortical surface-based perfusion maps was scored as optimal in 72 % in both cases. Cortical surface-based ASL maps provided a more global view than single slices and an accurate approach of brain perfusion in EOAD patients. CONCLUSIONS: Cortical surface-based analysis of ASL maps is technically feasible with a good image quality and may enable significant improvement in the detection of focal perfusion alterations in neurodegenerative disorders in the real-life clinical setting. CONCLUSIONS: • Arterial spin labelling is a promising sequence for assessing Alzheimer's disease. • Optimization of ASL brain perfusion image quality is crucial for image interpretation. • Cortical surface-based analysis may improve detection of perfusion alterations in a real-life clinical setting.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CHU Lille
CNRS
Inserm
Université de Lille
CNRS
Inserm
Université de Lille
Collections :
Research team(s) :
Troubles cognitifs dégénératifs et vasculaires
Submission date :
2019-11-27T13:03:47Z