Dual-energy ct (dect) lung perfusion in ...
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
Dual-energy ct (dect) lung perfusion in pulmonary hypertension: concordance rate with v/q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (cteph)
Author(s) :
Masy, Matthieu [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Giordano, Jessica [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Petyt, Gregory [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Hossein-Foucher, Claude [Auteur]
Troubles cognitifs vasculaires et dégénératifs
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Kyheng, Maéva [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
De Groote, Pascal [Auteur]
Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE]
Bertout, Marie [Auteur]
523045|||Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE] (VALID)
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Lamblin, Nicolas [Auteur]
523045|||Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE] (VALID)
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Bervar, Jean-François [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Remy, Jacques [Auteur]
Remy, Martine [Auteur]
221576|||Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS] (VALID)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Giordano, Jessica [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Petyt, Gregory [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Hossein-Foucher, Claude [Auteur]
Troubles cognitifs vasculaires et dégénératifs
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Kyheng, Maéva [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
De Groote, Pascal [Auteur]
Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE]
Bertout, Marie [Auteur]
523045|||Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE] (VALID)
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Lamblin, Nicolas [Auteur]
523045|||Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE] (VALID)
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Bervar, Jean-François [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Remy, Jacques [Auteur]
Remy, Martine [Auteur]
221576|||Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS] (VALID)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Journal title :
European radiology
Abbreviated title :
Eur Radiol
Volume number :
28
Pages :
5100-5110
Publisher :
Springer Link
Publication date :
2018-05-30
ISSN :
0938-7994
English keyword(s) :
Pulmonary embolism
Pulmonary hypertension
CT angiography
Pulmonary hypertension
CT angiography
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
OBJECTIVE: To evaluate the concordance between DECT perfusion and ventilation/perfusion (V/Q) scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH).
METHODS: Eighty patients underwent V/Q ...
Show more >OBJECTIVE: To evaluate the concordance between DECT perfusion and ventilation/perfusion (V/Q) scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: Eighty patients underwent V/Q scintigraphy and DECT perfusion on a 2nd- and 3rd-generation dual-source CT system. The imaging criteria for diagnosing CTEPH relied on at least one segmental triangular perfusion defect on DECT perfusion studies and V/Q mismatch on scintigraphy examinations. RESULTS: Based on multidisciplinary expert decisions that did not include DECT perfusion, 36 patients were diagnosed with CTEPH and 44 patients with other aetiologies of PH. On DECT perfusion studies, there were 35 true positives, 6 false positives and 1 false negative (sensitivity 0.97, specificity 0.86, PPV 0.85, NPV 0.97). On V/Q scans, there were 35 true positives and 1 false negative (sensitivity 0.97, specificity 1, PPV 1, NPV 0.98). There was excellent agreement between CT perfusion and scintigraphy in diagnosing CTEPH (kappa value 0.80). Combined information from DECT perfusion and CT angiographic images enabled correct reclassification of the 6 false positives and the unique false negative case of DECT perfusion. CONCLUSIONS: There is excellent agreement between DECT perfusion and V/Q scintigraphy in diagnosing CTEPH. The diagnostic accuracy of DECT perfusion is reinforced by the morpho-functional analysis of data sets. CONCLUSIONS: • Chronic thromboembolic pulmonary hypertension (CTEPH) is potentially curable by surgery. • The triage of patients with pulmonary hypertension currently relies on scintigraphy. • Dual-energy CT (DECT) can provide standard diagnostic information and lung perfusion from a single acquisition. • There is excellent agreement between DECT perfusion and scintigraphy in separating CTEPH and non-CTEPH patients.Show less >
Show more >OBJECTIVE: To evaluate the concordance between DECT perfusion and ventilation/perfusion (V/Q) scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: Eighty patients underwent V/Q scintigraphy and DECT perfusion on a 2nd- and 3rd-generation dual-source CT system. The imaging criteria for diagnosing CTEPH relied on at least one segmental triangular perfusion defect on DECT perfusion studies and V/Q mismatch on scintigraphy examinations. RESULTS: Based on multidisciplinary expert decisions that did not include DECT perfusion, 36 patients were diagnosed with CTEPH and 44 patients with other aetiologies of PH. On DECT perfusion studies, there were 35 true positives, 6 false positives and 1 false negative (sensitivity 0.97, specificity 0.86, PPV 0.85, NPV 0.97). On V/Q scans, there were 35 true positives and 1 false negative (sensitivity 0.97, specificity 1, PPV 1, NPV 0.98). There was excellent agreement between CT perfusion and scintigraphy in diagnosing CTEPH (kappa value 0.80). Combined information from DECT perfusion and CT angiographic images enabled correct reclassification of the 6 false positives and the unique false negative case of DECT perfusion. CONCLUSIONS: There is excellent agreement between DECT perfusion and V/Q scintigraphy in diagnosing CTEPH. The diagnostic accuracy of DECT perfusion is reinforced by the morpho-functional analysis of data sets. CONCLUSIONS: • Chronic thromboembolic pulmonary hypertension (CTEPH) is potentially curable by surgery. • The triage of patients with pulmonary hypertension currently relies on scintigraphy. • Dual-energy CT (DECT) can provide standard diagnostic information and lung perfusion from a single acquisition. • There is excellent agreement between DECT perfusion and scintigraphy in separating CTEPH and non-CTEPH patients.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CHU Lille
Inserm
Institut Pasteur de Lille
Université de Lille
Inserm
Institut Pasteur de Lille
Université de Lille
Collections :
Submission date :
2019-12-09T18:19:36Z
2024-03-26T16:01:26Z
2024-03-26T16:01:26Z
Files
- s00330-018-5467-2.pdf
- Version éditeur
- Restricted access
- Access the document