Quality control and stability of ketamine, ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
PMID :
URL permanente :
Titre :
Quality control and stability of ketamine, remifentanil and sufentanil syringes in a pediatric operating theater
Auteur(s) :
Bourdon, Florence [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Simon, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lannoy, Damien [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Berneron, Christophe [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Décaudin, Bertrand [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Reumaux, Laurence [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Richart, Pierre [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Odou, Pascal [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Simon, Nicolas [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lannoy, Damien [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Berneron, Christophe [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Décaudin, Bertrand [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Reumaux, Laurence [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Richart, Pierre [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Odou, Pascal [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Titre de la revue :
Pediatric Anesthesia
Nom court de la revue :
Paediatr Anaesth
Numéro :
29
Pagination :
193-199
Date de publication :
2019-02
ISSN :
1460-9592
Mot(s)-clé(s) en anglais :
sufentanil
ketamine
medication errors
syringe compounding
stability
remifentanil
ketamine
medication errors
syringe compounding
stability
remifentanil
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
BACKGROUND: Transforming a drug from its commercial form into a ready-to-use drug is common practice, especially in pediatrics. However, the risk of compounding error is real and data on drug stability in practice are not ...
Lire la suite >BACKGROUND: Transforming a drug from its commercial form into a ready-to-use drug is common practice, especially in pediatrics. However, the risk of compounding error is real and data on drug stability in practice are not always available. OBJECTIVE: The aim of this study was to assess, in real conditions, both the error rate and stability of three drugs: ketamine, remifentanil, and sufentanil. METHODS: A new rapid and easy-to-use high-performance liquid chromatography method with a diode array detector has been developed and validated to quantify these drugs and detect their degradation products. Over a 1-month period, 151 syringes were collected in the postanesthesia care unit. Seventy-three were stock solution syringes containing a 10-fold dilution of commercial drugs and 78 were serial dilution syringes made from successive dilutions of stock solutions. A comparison between real and expected concentrations as well as the detection of possible degradation products was carried out on these samples. RESULTS: All stock solution syringes had good chemical stability throughout the working day. A 4-µg/mL remifentanil serial dilution syringe, however, had to be discarded as a degradation peak was detected. Overall, 15.3% (95% CI, 9.5-21.1%) of syringes had a drug concentration outside the ±10% acceptability range, that is, 11.0% (95% CI, 3.7-18.2%) and 19.5% (95% CI, 10.6%-28.4%) of stock and diluted syringes respectively, with drug amounts ranging from -25.3% to 22.0%. The highest error rates were observed with sufentanil syringes: 20% and 28% for stock solution and serial dilution, respectively. CONCLUSIONS: The study shows that stock solution syringes prepared in advance are chemically stable throughout the day, unlike certain serial dilution syringes, indicating that the latter should be prepared just before administration to ensure chemical stability. Our results show that the error rate for serial dilution syringes is twice that of stock solution. Different safety measures are under discussion and have to be further studied.Lire moins >
Lire la suite >BACKGROUND: Transforming a drug from its commercial form into a ready-to-use drug is common practice, especially in pediatrics. However, the risk of compounding error is real and data on drug stability in practice are not always available. OBJECTIVE: The aim of this study was to assess, in real conditions, both the error rate and stability of three drugs: ketamine, remifentanil, and sufentanil. METHODS: A new rapid and easy-to-use high-performance liquid chromatography method with a diode array detector has been developed and validated to quantify these drugs and detect their degradation products. Over a 1-month period, 151 syringes were collected in the postanesthesia care unit. Seventy-three were stock solution syringes containing a 10-fold dilution of commercial drugs and 78 were serial dilution syringes made from successive dilutions of stock solutions. A comparison between real and expected concentrations as well as the detection of possible degradation products was carried out on these samples. RESULTS: All stock solution syringes had good chemical stability throughout the working day. A 4-µg/mL remifentanil serial dilution syringe, however, had to be discarded as a degradation peak was detected. Overall, 15.3% (95% CI, 9.5-21.1%) of syringes had a drug concentration outside the ±10% acceptability range, that is, 11.0% (95% CI, 3.7-18.2%) and 19.5% (95% CI, 10.6%-28.4%) of stock and diluted syringes respectively, with drug amounts ranging from -25.3% to 22.0%. The highest error rates were observed with sufentanil syringes: 20% and 28% for stock solution and serial dilution, respectively. CONCLUSIONS: The study shows that stock solution syringes prepared in advance are chemically stable throughout the day, unlike certain serial dilution syringes, indicating that the latter should be prepared just before administration to ensure chemical stability. Our results show that the error rate for serial dilution syringes is twice that of stock solution. Different safety measures are under discussion and have to be further studied.Lire moins >