Immobilisation of an anti-platelet adhesion ...
Document type :
Article dans une revue scientifique: Article original
Permalink :
Title :
Immobilisation of an anti-platelet adhesion and anti-thrombotic drug (EP224283) on polydopamine coated vascular stent promoting anti-thrombogenic properties
Author(s) :
Bricout, Nicolas [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Chai, Feng [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Sobocinski, Jonathan [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Laure, William [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Ung, Alexandre [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Woisel, Patrice [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Lyskawa, Joel [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Blanchemain, Nicolas [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Chai, Feng [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Sobocinski, Jonathan [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Laure, William [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Ung, Alexandre [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Woisel, Patrice [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Lyskawa, Joel [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Blanchemain, Nicolas [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Journal title :
Materials Science and Engineering: C
Abbreviated title :
Materials Science and Engineering: C
Pages :
110967
Publisher :
Elsevier BV
Publication date :
2020-08
ISSN :
0928-4931
HAL domain(s) :
Chimie/Matériaux
Sciences de l'ingénieur [physics]/Matériaux
Chimie/Polymères
Sciences de l'ingénieur [physics]/Génie des procédés
Sciences de l'ingénieur [physics]/Matériaux
Chimie/Polymères
Sciences de l'ingénieur [physics]/Génie des procédés
English abstract : [en]
Current vascular drug-eluting stents based on immuno-proliferative drugs would reduce the rate of in-stent restenosis (ISR) but may be associated with a higher risk of acute stent thrombosis due to non-selective activity. ...
Show more >Current vascular drug-eluting stents based on immuno-proliferative drugs would reduce the rate of in-stent restenosis (ISR) but may be associated with a higher risk of acute stent thrombosis due to non-selective activity. In this paper, we aimed to develop a polydopamine (PDA) coated chromium‑cobalt (CoCr) stent functionalised with EP224283 (Endotis Pharma SA), which combines both a GPIIbIIIa antagonist (tirofiban moiety) and a factor Xa inhibitor (idraparinux moiety) to reduce acute stent thrombosis. PDA-coated chromium‑cobalt (CoCr) samples were first immersed in a polyethylenimine (PEI, pH 8.5) solution to increase amine function density (36.0 ± 0.1 nmol/cm2) on the CoCr surface. In a second step, avidin was grafted onto CoCr-PDA-PEI through the biotin linkage (strategy 1) or directly by coupling reactions (strategy 2). The HABA titration proved the fixation of biotin onto CoCr-PDA-PEI surface with a density of 0.74 nmol/cm2. The fixation of avidin was demonstrated by water contact angle (WCA) and surface plasmon resonance (SPR). SEM micrograph shows the flexibility of the thin layer coated onto the stent after balloon inflation. Independently of the strategy, a qualitative SEM analysis showed a reduction in platelet activation when the molecule EP224283 was immobilised on avidin. In parallel, the measurement of anticoagulant activity (anti-Xa) revealed a higher anti-factor Xa activity (2.24 IU/mL vs. 0.09 IU/mL in control) when EP224283 was immobilised on avidin. Interestingly, after seven days of degradation, the anticoagulant activity was persistent in both strategies and looked more important with the strategy 2 than in strategy 1. Throughout this work, we developed an innovative vascular stent through the immobilisation of EP224283 onto CoCr-PDA-PEI-(avidin) system, which provides a promising solution to reduce ISR and thrombosis after stent implantation.Show less >
Show more >Current vascular drug-eluting stents based on immuno-proliferative drugs would reduce the rate of in-stent restenosis (ISR) but may be associated with a higher risk of acute stent thrombosis due to non-selective activity. In this paper, we aimed to develop a polydopamine (PDA) coated chromium‑cobalt (CoCr) stent functionalised with EP224283 (Endotis Pharma SA), which combines both a GPIIbIIIa antagonist (tirofiban moiety) and a factor Xa inhibitor (idraparinux moiety) to reduce acute stent thrombosis. PDA-coated chromium‑cobalt (CoCr) samples were first immersed in a polyethylenimine (PEI, pH 8.5) solution to increase amine function density (36.0 ± 0.1 nmol/cm2) on the CoCr surface. In a second step, avidin was grafted onto CoCr-PDA-PEI through the biotin linkage (strategy 1) or directly by coupling reactions (strategy 2). The HABA titration proved the fixation of biotin onto CoCr-PDA-PEI surface with a density of 0.74 nmol/cm2. The fixation of avidin was demonstrated by water contact angle (WCA) and surface plasmon resonance (SPR). SEM micrograph shows the flexibility of the thin layer coated onto the stent after balloon inflation. Independently of the strategy, a qualitative SEM analysis showed a reduction in platelet activation when the molecule EP224283 was immobilised on avidin. In parallel, the measurement of anticoagulant activity (anti-Xa) revealed a higher anti-factor Xa activity (2.24 IU/mL vs. 0.09 IU/mL in control) when EP224283 was immobilised on avidin. Interestingly, after seven days of degradation, the anticoagulant activity was persistent in both strategies and looked more important with the strategy 2 than in strategy 1. Throughout this work, we developed an innovative vascular stent through the immobilisation of EP224283 onto CoCr-PDA-PEI-(avidin) system, which provides a promising solution to reduce ISR and thrombosis after stent implantation.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
CNRS
INRA
ENSCL
CNRS
INRA
ENSCL
Collections :
Research team(s) :
Ingénierie des Systèmes Polymères
Submission date :
2020-06-11T07:45:19Z
2020-06-22T09:20:26Z
2020-06-22T09:20:26Z