The oticon medical neuro zti cochlear ...
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
The oticon medical neuro zti cochlear implant and the neuro 2 sound processor: multicentric evaluation of outcomes in adults and children
Author(s) :
Franco-Vidal, Valerie [Auteur]
CHU de Bordeaux Pellegrin [Bordeaux]
Parietti-Winkler, Cecile [Auteur]
Faculté de Médecine [Nancy]
Guevara, Nicolas [Auteur]
Institut Universitaire de la Face et du Cou [Nice]
Truy, Eric [Auteur]
Hospices Civils de Lyon [HCL]
Loundon, Natalie [Auteur]
Hôpital Necker - Enfants Malades [AP-HP]
Bailleux, Sonanda [Auteur]
Hôpitaux Pédiatriques de Nice Lenval [CHU-Lenval]
Ardoint, Marine [Auteur]
Oticon Medical / Neurelec
Saai, Sonia [Auteur]
Oticon Medical / Neurelec
Hoen, Michel [Auteur]
Oticon Medical / Neurelec
Laplante-Levesque, Ariane [Auteur]
Oticon Medical / Neurelec
Linköpings Universitet = Linköping University
Mosnier, Isabelle [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Bordure, Philippe [Auteur]
Centre Hospitalier Universitaire de Nantes = Nantes University Hospital [CHU Nantes]
Vincent, Christophe [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
CHU de Bordeaux Pellegrin [Bordeaux]
Parietti-Winkler, Cecile [Auteur]
Faculté de Médecine [Nancy]
Guevara, Nicolas [Auteur]
Institut Universitaire de la Face et du Cou [Nice]
Truy, Eric [Auteur]
Hospices Civils de Lyon [HCL]
Loundon, Natalie [Auteur]
Hôpital Necker - Enfants Malades [AP-HP]
Bailleux, Sonanda [Auteur]
Hôpitaux Pédiatriques de Nice Lenval [CHU-Lenval]
Ardoint, Marine [Auteur]
Oticon Medical / Neurelec
Saai, Sonia [Auteur]
Oticon Medical / Neurelec
Hoen, Michel [Auteur]
Oticon Medical / Neurelec
Laplante-Levesque, Ariane [Auteur]
Oticon Medical / Neurelec
Linköpings Universitet = Linköping University
Mosnier, Isabelle [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Bordure, Philippe [Auteur]
Centre Hospitalier Universitaire de Nantes = Nantes University Hospital [CHU Nantes]
Vincent, Christophe [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Journal title :
International Journal of Audiology
Abbreviated title :
Int J Audiol
Pages :
153-160
Publication date :
2019-10-04
ISSN :
1708-8186
Keyword(s) :
speech perception
Oticon Medical Neuro Zti and Neuro 2
cochlear implantation
sound processor
Oticon Medical Neuro Zti and Neuro 2
cochlear implantation
sound processor
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
Objective: This study evaluated the outcomes of the Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor.
Design: Neuro One users were upgraded to Neuro 2. Monosyllabic word identification was ...
Show more >Objective: This study evaluated the outcomes of the Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor. Design: Neuro One users were upgraded to Neuro 2. Monosyllabic word identification was evaluated in adults with Neuro One after ≥5 months, with Neuro 2 at upgrade, and with Neuro 2 after 3 months. Self-reported listening ability, satisfaction, and usability were measured in adults and children. Study sample: Participants were 44 adults and 26 children. Results: Speech identification scores in quiet and noise were 58% and 45% with Neuro One and 67% and 55% with Neuro 2 after 3 months, respectively. Hearing impairment duration and number of active electrodes significantly predicted speech identification in noise with Neuro 2. Significantly higher questionnaire ratings were obtained for Neuro 2 than Neuro One regarding listening ability in complex listening situations, comfort and music, as well as nine aspects of satisfaction and usability. Conclusion: This study demonstrates the clinical superiority of the Neuro 2 sound processor over Neuro One in terms of speech identification in quiet and in noise and reported patient benefit and satisfaction. Given the study design, sources of improvement may include factors unrelated to the sound processor itself.Show less >
Show more >Objective: This study evaluated the outcomes of the Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor. Design: Neuro One users were upgraded to Neuro 2. Monosyllabic word identification was evaluated in adults with Neuro One after ≥5 months, with Neuro 2 at upgrade, and with Neuro 2 after 3 months. Self-reported listening ability, satisfaction, and usability were measured in adults and children. Study sample: Participants were 44 adults and 26 children. Results: Speech identification scores in quiet and noise were 58% and 45% with Neuro One and 67% and 55% with Neuro 2 after 3 months, respectively. Hearing impairment duration and number of active electrodes significantly predicted speech identification in noise with Neuro 2. Significantly higher questionnaire ratings were obtained for Neuro 2 than Neuro One regarding listening ability in complex listening situations, comfort and music, as well as nine aspects of satisfaction and usability. Conclusion: This study demonstrates the clinical superiority of the Neuro 2 sound processor over Neuro One in terms of speech identification in quiet and in noise and reported patient benefit and satisfaction. Given the study design, sources of improvement may include factors unrelated to the sound processor itself.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CHU Lille
Inserm
Université de Lille
Inserm
Université de Lille
Collections :
Submission date :
2021-01-20T15:59:21Z
2024-02-23T13:32:54Z
2024-02-23T13:32:54Z
Files
- The Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor multicentric evaluation of outcomes in adults and children.pdf
- Non spécifié
- Open access
- Access the document