Trace elements in e-liquids - Development ...
Type de document :
Article dans une revue scientifique
PMID :
URL permanente :
Titre :
Trace elements in e-liquids - Development and validation of an ICP-MS method for the analysis of electronic cigarette refills
Auteur(s) :
Beauval, Nicolas [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Howsam, M [Auteur]
Anthérieu, Sébastien [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Allorge, Delphine [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Soyez, Melissa [Auteur]
Garcon, Guillaume [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Goossens, Jean-Francois [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lo Guidice, Jean-Marc [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Garat, Anne [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Howsam, Michael [Auteur]
Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Howsam, M [Auteur]
Anthérieu, Sébastien [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Allorge, Delphine [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Soyez, Melissa [Auteur]
Garcon, Guillaume [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Goossens, Jean-Francois [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lo Guidice, Jean-Marc [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Garat, Anne [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Howsam, Michael [Auteur]
Facteurs de Risque et Déterminants Moléculaires des Maladies liées au Vieillissement - U 1167 [RID-AGE]
Titre de la revue :
Regulatory toxicology and pharmacology
Nom court de la revue :
Regul. Toxicol. Pharmacol.
Numéro :
79
Pagination :
144-148
Date de publication :
2016
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé :
Electronic cigarette use has rapidly increased in recent years. In assessing their safety, and in view of coming regulations, trace elements (TE) are among the potentially toxic compounds required to be evaluated in ...
Lire la suite >Electronic cigarette use has rapidly increased in recent years. In assessing their safety, and in view of coming regulations, trace elements (TE) are among the potentially toxic compounds required to be evaluated in electronic cigarette refill fluids ("e-liquids"). An analytical method using inductively coupled plasma with mass spectrometric detection (ICP-MS) was developed and rigorously validated in order to determine concentrations of 15 TE in 54 e-liquids from a French brand. Despite a significant matrix effect from the main e-liquid constituents, and difficulties related to the current lack of reference materials, our method demonstrated satisfactory linearity, precision and robustness, and permitted the quantification of low concentrations of these 15 elements: lower limits of quantification (LLQ) obtained were ≤4 ppb for all elements except for Ni, Cu and Zn (16 ppb, 20 ppb and 200 ppb, respectively). All TE concentrations in all tested samples were <510 ppb, mostly near or below the LLQs. This method is transposable and is timely for laboratories seeking to meet a prospective demand in light of current or future regulations.Lire moins >
Lire la suite >Electronic cigarette use has rapidly increased in recent years. In assessing their safety, and in view of coming regulations, trace elements (TE) are among the potentially toxic compounds required to be evaluated in electronic cigarette refill fluids ("e-liquids"). An analytical method using inductively coupled plasma with mass spectrometric detection (ICP-MS) was developed and rigorously validated in order to determine concentrations of 15 TE in 54 e-liquids from a French brand. Despite a significant matrix effect from the main e-liquid constituents, and difficulties related to the current lack of reference materials, our method demonstrated satisfactory linearity, precision and robustness, and permitted the quantification of low concentrations of these 15 elements: lower limits of quantification (LLQ) obtained were ≤4 ppb for all elements except for Ni, Cu and Zn (16 ppb, 20 ppb and 200 ppb, respectively). All TE concentrations in all tested samples were <510 ppb, mostly near or below the LLQs. This method is transposable and is timely for laboratories seeking to meet a prospective demand in light of current or future regulations.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
CHU Lille
Institut Pasteur de Lille
CHU Lille
Institut Pasteur de Lille
Collections :
Équipe(s) de recherche :
Modélisation biopharmaceutique et pharmacocinétique
Date de dépôt :
2019-02-26T17:11:45Z
2021-05-12T07:21:33Z
2021-05-27T14:57:34Z
2021-05-12T07:21:33Z
2021-05-27T14:57:34Z