Electronic Scheme for Multiplexed Dynamic ...
Type de document :
Compte-rendu et recension critique d'ouvrage
DOI :
Titre :
Electronic Scheme for Multiplexed Dynamic Behavior Excitation and Detection of Piezoelectric Silicon-Based Micromembranes
Auteur(s) :
Ayela, Cédric [Auteur]
Laboratoire de l'intégration, du matériau au système [IMS]
Alava, Thomas [Auteur]
Laboratoire d'analyse et d'architecture des systèmes [LAAS]
Lagrange, Denis [Auteur]
Service Instrumentation Conception Caractérisation [LAAS-I2C]
Remiens, Denis [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Soyer, Caroline [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Ondarçuhu, Thierry [Auteur]
Centre d'élaboration de matériaux et d'études structurales [CEMES]
Greve, Anders [Auteur]
Nicu, Liviu [Auteur]
Équipe NanoBioSystèmes [LAAS-NBS]
Laboratoire de l'intégration, du matériau au système [IMS]
Alava, Thomas [Auteur]
Laboratoire d'analyse et d'architecture des systèmes [LAAS]
Lagrange, Denis [Auteur]
Service Instrumentation Conception Caractérisation [LAAS-I2C]
Remiens, Denis [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Soyer, Caroline [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Ondarçuhu, Thierry [Auteur]
Centre d'élaboration de matériaux et d'études structurales [CEMES]
Greve, Anders [Auteur]
Nicu, Liviu [Auteur]
Équipe NanoBioSystèmes [LAAS-NBS]
Titre de la revue :
IEEE Sensors Journal
Pagination :
210-217
Éditeur :
Institute of Electrical and Electronics Engineers
Date de publication :
2008-03
ISSN :
1530-437X
Discipline(s) HAL :
Sciences de l'ingénieur [physics]/Micro et nanotechnologies/Microélectronique
Résumé en anglais : [en]
A new concept for a precise compensation of the static capacitance of piezoelectric silicon-based micromembranes is proposed. Combining analog and digital field-programmable gate array hardware elements with specific ...
Lire la suite >A new concept for a precise compensation of the static capacitance of piezoelectric silicon-based micromembranes is proposed. Combining analog and digital field-programmable gate array hardware elements with specific software treatment, this system enables the parallel excitation and detection of the resonant frequencies (and the quality factors) of matrices of piezoelectric micromembranes integrated on the same chip. The frequency measurement stability is less than 1 ppm (1-2 Hz) with a switching capability of 4 micromembranes/sec and a measurement bandwidth of 1.5 MHz. The real-time multiplexed tracking of the resonant frequency and quality factor on several micromembranes is performed in different liquid media, showing the high capability of measurement on dramatically attenuated signals. Prior to these measurements, calibration in air is done making use of silica microbeads successive depositions onto piezoelectric membranes surface. The mass sensitivity in air is, thus, estimated at, in excellent agreement with the theoretical corresponding value.Lire moins >
Lire la suite >A new concept for a precise compensation of the static capacitance of piezoelectric silicon-based micromembranes is proposed. Combining analog and digital field-programmable gate array hardware elements with specific software treatment, this system enables the parallel excitation and detection of the resonant frequencies (and the quality factors) of matrices of piezoelectric micromembranes integrated on the same chip. The frequency measurement stability is less than 1 ppm (1-2 Hz) with a switching capability of 4 micromembranes/sec and a measurement bandwidth of 1.5 MHz. The real-time multiplexed tracking of the resonant frequency and quality factor on several micromembranes is performed in different liquid media, showing the high capability of measurement on dramatically attenuated signals. Prior to these measurements, calibration in air is done making use of silica microbeads successive depositions onto piezoelectric membranes surface. The mass sensitivity in air is, thus, estimated at, in excellent agreement with the theoretical corresponding value.Lire moins >
Langue :
Anglais
Vulgarisation :
Non
Source :