Fuzzy observer-based fault tolerant control ...
Type de document :
Compte-rendu et recension critique d'ouvrage
Titre :
Fuzzy observer-based fault tolerant control against sensor faults for proton exchange membrane fuel cells
Auteur(s) :
Titre de la revue :
International Journal of Hydrogen Energy
Pagination :
11220-11232
Éditeur :
Elsevier
Date de publication :
2020-01
ISSN :
0360-3199
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
In this paper, robust fault diagnosis problem of Proton Exchange Membrane Fuel Cells (PEMFC) is presented based on Takagi-Sugeno (TS) Fuzzy Unknown Input Observer (FUIO). TS FUIO based on Linear Matrix Equalities (LMEs) ...
Lire la suite >In this paper, robust fault diagnosis problem of Proton Exchange Membrane Fuel Cells (PEMFC) is presented based on Takagi-Sugeno (TS) Fuzzy Unknown Input Observer (FUIO). TS FUIO based on Linear Matrix Equalities (LMEs) and the Linear Matrix Inequalities (LMIs) are design. Firstly, the nonlinear PEMFC system with sensor faults and disturbance is represented by TS fuzzy model. Then, a FUIO and sensor fault estimation algorithm is developed and then a model based Fuzzy Fault Tolerant Controller design uses the concept of Parallel Distributed Compensation (PDC). Sufficient stability conditions are studied based on LMIs and LMEs. In order to verify the proposed approach, a PEMFC system with return manifold pressure and hydrogen mass sensors fault and disturbance was tested to illustrate the effectiveness of the proposed strategyLire moins >
Lire la suite >In this paper, robust fault diagnosis problem of Proton Exchange Membrane Fuel Cells (PEMFC) is presented based on Takagi-Sugeno (TS) Fuzzy Unknown Input Observer (FUIO). TS FUIO based on Linear Matrix Equalities (LMEs) and the Linear Matrix Inequalities (LMIs) are design. Firstly, the nonlinear PEMFC system with sensor faults and disturbance is represented by TS fuzzy model. Then, a FUIO and sensor fault estimation algorithm is developed and then a model based Fuzzy Fault Tolerant Controller design uses the concept of Parallel Distributed Compensation (PDC). Sufficient stability conditions are studied based on LMIs and LMEs. In order to verify the proposed approach, a PEMFC system with return manifold pressure and hydrogen mass sensors fault and disturbance was tested to illustrate the effectiveness of the proposed strategyLire moins >
Langue :
Anglais
Vulgarisation :
Non
Collections :
Source :