EM emissions induced by a DC/DC power ...
Type de document :
Communication dans un congrès avec actes
Titre :
EM emissions induced by a DC/DC power converter: first experiments on a laboratory system
Auteur(s) :
Chiappori, Guido, Jose [Auteur]
Baranowski, Sylvie [Auteur]
COMmunications NUMériques - IEMN [COMNUM - IEMN]
Cohin, O. [Auteur]
Baranowski, Sylvie [Auteur]
COMmunications NUMériques - IEMN [COMNUM - IEMN]
Cohin, O. [Auteur]
Titre de la manifestation scientifique :
2014 International Symposium on Electromagnetic Compatibility - EMC EUROPE
Ville :
Gothenburg
Pays :
Suède
Date de début de la manifestation scientifique :
2014-09-01
Titre de l’ouvrage :
Proceedings of 2014 International Symposium on Electromagnetic Compatibility
Éditeur :
IEEE
Mot(s)-clé(s) en anglais :
Magnetic field radiation
Power converter
Nearfield measurements
Power converter
Nearfield measurements
Discipline(s) HAL :
Informatique [cs]/Réseaux et télécommunications [cs.NI]
Sciences de l'ingénieur [physics]/Traitement du signal et de l'image [eess.SP]
Informatique [cs]/Intelligence artificielle [cs.AI]
Sciences de l'ingénieur [physics]/Electronique
Sciences de l'ingénieur [physics]/Traitement du signal et de l'image [eess.SP]
Informatique [cs]/Intelligence artificielle [cs.AI]
Sciences de l'ingénieur [physics]/Electronique
Résumé en anglais : [en]
This paper deals with the emissions induced by a power converter. The final aim is to achieve an optimal design of a power converter printed circuit board (PCB) in the early stage of simulation. This study is focused on a ...
Lire la suite >This paper deals with the emissions induced by a power converter. The final aim is to achieve an optimal design of a power converter printed circuit board (PCB) in the early stage of simulation. This study is focused on a well known Buck converter which operates at a frequency around 1MHz. The load loop was performed of exaggerated dimensions to highlight the problem of radiation and to allow an analysis in detail. Taken into account the frequency and the structure of the converter, this first approach is focused on magnetic field. In order to evaluate the near field probe effects on the measurements results, the system `converter-probe' is modeled using 3-D software (CST MWS) and then, the electromagnetic field radiated by the power converter is calculated and the results are compared with measurements. Two probes are studied, an industrial one and another made in laboratory. The comparison of simulations and measurements results are presented in order to evaluate the emissions induced by the converter and to study the influence of the probe in the measurement.Lire moins >
Lire la suite >This paper deals with the emissions induced by a power converter. The final aim is to achieve an optimal design of a power converter printed circuit board (PCB) in the early stage of simulation. This study is focused on a well known Buck converter which operates at a frequency around 1MHz. The load loop was performed of exaggerated dimensions to highlight the problem of radiation and to allow an analysis in detail. Taken into account the frequency and the structure of the converter, this first approach is focused on magnetic field. In order to evaluate the near field probe effects on the measurements results, the system `converter-probe' is modeled using 3-D software (CST MWS) and then, the electromagnetic field radiated by the power converter is calculated and the results are compared with measurements. Two probes are studied, an industrial one and another made in laboratory. The comparison of simulations and measurements results are presented in order to evaluate the emissions induced by the converter and to study the influence of the probe in the measurement.Lire moins >