Long term behavior of dexamethasone-loaded ...
Type de document :
Article dans une revue scientifique: Article original
PMID :
URL permanente :
Titre :
Long term behavior of dexamethasone-loaded cochlear implants: In vitro & in vivo
Auteur(s) :
Rongthong, T. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Qnouch, Adam [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Gehrke, M. M. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Danede, Florence [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Willart, Jean-François [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
De Oliveira, P. F. M. [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Paccou, Laurent [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Tourrel, G. [Auteur]
Oticon Medical / Neurelec
Stahl, P. [Auteur]
Verin, Jérémy [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Toulemonde, Philippine [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Vincent, Christophe [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Florence [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Juergen [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Qnouch, Adam [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Gehrke, M. M. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Danede, Florence [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Willart, Jean-François [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
De Oliveira, P. F. M. [Auteur]
Unité Matériaux et Transformations - UMR 8207 [UMET]
Paccou, Laurent [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Tourrel, G. [Auteur]
Oticon Medical / Neurelec
Stahl, P. [Auteur]
Verin, Jérémy [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Toulemonde, Philippine [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Vincent, Christophe [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Florence [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Juergen [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Titre de la revue :
International Journal of Pharmaceutics: X
Nom court de la revue :
Int J Pharm X
Numéro :
4
Pagination :
100141
Date de publication :
2022-12-06
ISSN :
2590-1567
Mot(s)-clé(s) :
Cochlear implant
Dexamethasone
Silicone
Raman imaging
Diffusion
Dexamethasone
Silicone
Raman imaging
Diffusion
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
The aim of this study was to better understand the long term behavior of silicone-based cochlear implants loaded with dexamethasone: in vitro as well as in vivo (gerbils). This type of local controlled drug delivery systems ...
Lire la suite >The aim of this study was to better understand the long term behavior of silicone-based cochlear implants loaded with dexamethasone: in vitro as well as in vivo (gerbils). This type of local controlled drug delivery systems offers an interesting potential for the treatment of hearing loss. Because very long release periods are targeted (several years/decades), product optimization is highly challenging. Up to now, only little is known on the long term behavior of these systems, including their drug release patterns as well as potential swelling or shrinking upon exposure to aqueous media or living tissue. Different types of cylindrical, cochlear implants were prepared by injection molding, varying their dimensions (being suitable for use in humans or gerbils) and initial drug loading (0, 1 or 10%). Dexamethasone release was monitored in vitro upon exposure to artificial perilymph at 37 °C for >3 years. Optical microscopy, X-ray diffraction and Raman imaging were used to characterize the implants before and after exposure to the release medium in vitro, as well as after 2 years implantation in gerbils. Importantly, in all cases dexamethasone release was reliably controlled during the observation periods. Diffusional mass transport and limited drug solubility effects within the silicone matrices seem to play a major role. Initially, the dexamethasone is homogeneously distributed throughout the polymeric matrices in the form of tiny crystals. Upon exposure to aqueous media or living tissue, limited amounts of water penetrate into the implant, dissolve the drug, which subsequently diffuses out. Surface-near regions are depleted first, resulting in an increase in the apparent drug diffusivity with time. No evidence for noteworthy implant swelling or shrinkage was observed in vitro, nor in vivo. A simplified mathematical model can be used to facilitate drug product optimization, allowing the prediction of the resulting drug release rates during decades as a function of the implant's design.Lire moins >
Lire la suite >The aim of this study was to better understand the long term behavior of silicone-based cochlear implants loaded with dexamethasone: in vitro as well as in vivo (gerbils). This type of local controlled drug delivery systems offers an interesting potential for the treatment of hearing loss. Because very long release periods are targeted (several years/decades), product optimization is highly challenging. Up to now, only little is known on the long term behavior of these systems, including their drug release patterns as well as potential swelling or shrinking upon exposure to aqueous media or living tissue. Different types of cylindrical, cochlear implants were prepared by injection molding, varying their dimensions (being suitable for use in humans or gerbils) and initial drug loading (0, 1 or 10%). Dexamethasone release was monitored in vitro upon exposure to artificial perilymph at 37 °C for >3 years. Optical microscopy, X-ray diffraction and Raman imaging were used to characterize the implants before and after exposure to the release medium in vitro, as well as after 2 years implantation in gerbils. Importantly, in all cases dexamethasone release was reliably controlled during the observation periods. Diffusional mass transport and limited drug solubility effects within the silicone matrices seem to play a major role. Initially, the dexamethasone is homogeneously distributed throughout the polymeric matrices in the form of tiny crystals. Upon exposure to aqueous media or living tissue, limited amounts of water penetrate into the implant, dissolve the drug, which subsequently diffuses out. Surface-near regions are depleted first, resulting in an increase in the apparent drug diffusivity with time. No evidence for noteworthy implant swelling or shrinkage was observed in vitro, nor in vivo. A simplified mathematical model can be used to facilitate drug product optimization, allowing the prediction of the resulting drug release rates during decades as a function of the implant's design.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
Inserm
CHU Lille
Inserm
CHU Lille
Collections :
Équipe(s) de recherche :
Matériaux Moléculaires et Thérapeutiques
Date de dépôt :
2023-02-22T01:29:12Z
2023-03-03T13:24:34Z
2023-03-03T13:24:34Z
Fichiers
- 1-s2.0-S2590156722000329-main.pdf
- Version éditeur
- Accès libre
- Accéder au document