In situ degradation of organophosphorus ...
Type de document :
Article dans une revue scientifique: Article original
URL permanente :
Titre :
In situ degradation of organophosphorus flame retardant on cellulosic fabric using advanced oxidation process: A study on degradation and characterization
Auteur(s) :
Yasin, Sohail [Auteur]
Université de Lille
École nationale supérieure des arts et industries textiles [ENSAIT]
Massika Behary, Nemeshwaree [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Giraud, Stephane [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Perwuelz, Anne [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Université de Lille
École nationale supérieure des arts et industries textiles [ENSAIT]
Massika Behary, Nemeshwaree [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Giraud, Stephane [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Perwuelz, Anne [Auteur]
Ecole nationale supérieure des arts et industries textiles de Roubaix (ENSAIT)
Titre de la revue :
Polymer Degradation and Stability
Nom court de la revue :
Polym. Degrad. Stabil.
Numéro :
126
Pagination :
1-8
Date de publication :
2016-02-02
ISSN :
0141-3910
Mot(s)-clé(s) en anglais :
Organophosphorus
Flame retardant
Cotton
Degradation
Fenton reactions
Flame retardant
Cotton
Degradation
Fenton reactions
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
N-methylol dimethyl phosphonopropionamide (MDPA) is one of the most effective organophosphorus flame retardants for cellulosic fabrics, used in combination with Trimethylol melamine (TMM) to obtain durable and improved ...
Lire la suite >N-methylol dimethyl phosphonopropionamide (MDPA) is one of the most effective organophosphorus flame retardants for cellulosic fabrics, used in combination with Trimethylol melamine (TMM) to obtain durable and improved flame retardant properties. While their use is responsible for severe health problems, there is a need today to study methods to eliminate or degrade the durable flame retardant products which stay on discarded flame retardant textiles. The final aim is to improve the reusability of discarded textiles and to increase their energetic yield during the incineration phase. In this work, the degradation and mineralization of the flame retardant MDPA on cellulosic fabric, was studied using an advanced oxidation process (AOP) based on Fenton reaction. The effect of varying concentrations of Fenton's reagents (H2O2 and Fe2+ in aqueous medium) on the degradation of the MDPA was studied. The degradation of MDPA in aqueous media was monitored by measuring chemical oxygen demand (COD) of the reaction mixture over time. The mechanical properties of the cellulosic fabric after Fenton's reaction were unaltered in both warp and weft directions. The flammability test and thermogravimetric (TGA and DTG) results confirmed the degradation of MDPA flame retardant from the fabric. Pyrolysis combustion flow calorimeter (PCFC) confirms that there is a higher heat release after Fenton's reaction degradation which makes the degraded flame retardant cotton interesting for energy production by incineration.Lire moins >
Lire la suite >N-methylol dimethyl phosphonopropionamide (MDPA) is one of the most effective organophosphorus flame retardants for cellulosic fabrics, used in combination with Trimethylol melamine (TMM) to obtain durable and improved flame retardant properties. While their use is responsible for severe health problems, there is a need today to study methods to eliminate or degrade the durable flame retardant products which stay on discarded flame retardant textiles. The final aim is to improve the reusability of discarded textiles and to increase their energetic yield during the incineration phase. In this work, the degradation and mineralization of the flame retardant MDPA on cellulosic fabric, was studied using an advanced oxidation process (AOP) based on Fenton reaction. The effect of varying concentrations of Fenton's reagents (H2O2 and Fe2+ in aqueous medium) on the degradation of the MDPA was studied. The degradation of MDPA in aqueous media was monitored by measuring chemical oxygen demand (COD) of the reaction mixture over time. The mechanical properties of the cellulosic fabric after Fenton's reaction were unaltered in both warp and weft directions. The flammability test and thermogravimetric (TGA and DTG) results confirmed the degradation of MDPA flame retardant from the fabric. Pyrolysis combustion flow calorimeter (PCFC) confirms that there is a higher heat release after Fenton's reaction degradation which makes the degraded flame retardant cotton interesting for energy production by incineration.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
ENSAIT
Junia HEI
ENSAIT
Junia HEI
Collections :
Date de dépôt :
2023-06-20T06:50:44Z
2024-03-06T09:40:52Z
2024-03-06T09:40:52Z