Stability of trace element concentrations ...
Type de document :
Article dans une revue scientifique: Article original
PMID :
URL permanente :
Titre :
Stability of trace element concentrations in frozen urine - Effect on different elements of more than 10 years at -80°C
Auteur(s) :
Beauval, Nicolas [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Leroyer, Ariane [Auteur]
Institut de Recherche Translationnelle sur l'Inflammation (INFINITE) - U1286
Hisbergues, Michael [Auteur]
Allorge, Delphine [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Maboudou, Patrice [Auteur]
Howsam, Michael [Auteur]
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Nisse, Catherine [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Leroyer, Ariane [Auteur]
Institut de Recherche Translationnelle sur l'Inflammation (INFINITE) - U1286
Hisbergues, Michael [Auteur]
Allorge, Delphine [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Maboudou, Patrice [Auteur]
Howsam, Michael [Auteur]
Facteurs de risque et déterminants moléculaires des maladies liées au vieillissement (RID-AGE) - U1167
Nisse, Catherine [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Titre de la revue :
Journal of Trace Elements in Medicine and Biology
Nom court de la revue :
J Trace Elem Med Biol
Numéro :
74
Pagination :
127080
Éditeur :
Elsevier
Date de publication :
2022-10-02
ISSN :
0946-672X
Mot(s)-clé(s) en anglais :
Trace elements
Stability
Freezing
Urine
Biobanking
ICP-MS
Stability
Freezing
Urine
Biobanking
ICP-MS
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Chimie
Chimie
Résumé en anglais : [en]
Background
Analysis of urinary trace elements is widely used in Human Biology, especially in occupational and environmental biomonitoring. Collections of urine samples are of great interest for those studying trace ...
Lire la suite >Background Analysis of urinary trace elements is widely used in Human Biology, especially in occupational and environmental biomonitoring. Collections of urine samples are of great interest for those studying trace elements but many of them are actually unused, in part perhaps because of a lack of knowledge about the stability of trace element concentrations under such storage conditions. The aim of this study was to evaluate the impact of a long-term frozen storage on the measurement of the urinary concentration of 10 trace elements. Method Forty-eight urinary samples were re-analysed by inductively coupled plasma mass spectrometry (ICP-MS) for the quantification of As, Cd, Co, Cr, Mn, Ni, Pb, Sb, Tl, and Zn, after 11–13 years of frozen storage at − 80 °C. Results A slight water loss likely occurred, even at − 80 °C, but seems to be compensated by using creatinine-adjusted concentrations. Concentrations of As, Cd, Pb, Tl, Zn, and possibly Mn, did not suffer from major modification during storage, while the plastic container likely contaminated samples with Sb. The technological evolution over 13 years may have affected some results, especially those with lower concentrations, and must be taken into account when comparing data over time. Conclusion This study provides some promising preliminary data on the stability of trace element concentrations during long-term frozen storage, and some evidence that urine samples in existing biobanks remain a valuable resource, even if they were collected many years ago.Lire moins >
Lire la suite >Background Analysis of urinary trace elements is widely used in Human Biology, especially in occupational and environmental biomonitoring. Collections of urine samples are of great interest for those studying trace elements but many of them are actually unused, in part perhaps because of a lack of knowledge about the stability of trace element concentrations under such storage conditions. The aim of this study was to evaluate the impact of a long-term frozen storage on the measurement of the urinary concentration of 10 trace elements. Method Forty-eight urinary samples were re-analysed by inductively coupled plasma mass spectrometry (ICP-MS) for the quantification of As, Cd, Co, Cr, Mn, Ni, Pb, Sb, Tl, and Zn, after 11–13 years of frozen storage at − 80 °C. Results A slight water loss likely occurred, even at − 80 °C, but seems to be compensated by using creatinine-adjusted concentrations. Concentrations of As, Cd, Pb, Tl, Zn, and possibly Mn, did not suffer from major modification during storage, while the plastic container likely contaminated samples with Sb. The technological evolution over 13 years may have affected some results, especially those with lower concentrations, and must be taken into account when comparing data over time. Conclusion This study provides some promising preliminary data on the stability of trace element concentrations during long-term frozen storage, and some evidence that urine samples in existing biobanks remain a valuable resource, even if they were collected many years ago.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
CHU Lille
Institut Pasteur de Lille
CHU Lille
Institut Pasteur de Lille
Collections :
Date de dépôt :
2023-10-20T06:00:43Z
2024-02-29T13:34:38Z
2024-02-29T13:34:38Z
Fichiers
- Beauval et al.pdf
- Version éditeur
- Accès restreint
- Accéder au document