Non-Enzymatic Glucose Sensing Using Carbon ...
Type de document :
Article dans une revue scientifique
DOI :
URL permanente :
Titre :
Non-Enzymatic Glucose Sensing Using Carbon Quantum Dots Decorated with Copper Oxide Nanoparticles
Auteur(s) :
Maaoui, Houcem [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Teodoresu, Florina [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Wang, Qian [Auteur]
Changchun Institute of Technology
Pan, Guo-Hui [Auteur]
Changchun Institute of Technology
Addad, Ahmed [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Chtourou, Radhouane [Auteur]
Université virtuelle de Tunis [UVT]
Szunerits, Sabine [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Boukherroub, Rabah [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Teodoresu, Florina [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Wang, Qian [Auteur]
Changchun Institute of Technology
Pan, Guo-Hui [Auteur]
Changchun Institute of Technology
Addad, Ahmed [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Chtourou, Radhouane [Auteur]
Université virtuelle de Tunis [UVT]
Szunerits, Sabine [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Boukherroub, Rabah [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Titre de la revue :
Sensors
Numéro :
16
Pagination :
1720
Éditeur :
MDPI
Date de publication :
2016-10-18
ISSN :
1424-8220
Discipline(s) HAL :
Chimie
Résumé en anglais : [en]
Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes) leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate ...
Lire la suite >Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes) leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate detection of glucose in the blood at low cost remains a challenging task, although it is of great importance for the diagnosis and therapy of diabetic patients. In this work, carbon quantum dots decorated with copper oxide nanostructures (CQDs/Cu2O) are prepared by a simple hydrothermal approach, and their potential for electrochemical non-enzymatic glucose sensing is evaluated. The proposed sensor exhibits excellent electrocatalytic activity towards glucose oxidation in alkaline solutions. The glucose sensor is characterized by a wide concentration range from 6 µM to 6 mM, a sensitivity of 2.9 ± 0.2 µA·µM−1·cm−2, and a detection limit of 6 µM at a signal-to-noise ratio S/N = 3. The sensors are successfully applied for glucose determination in human serum samples, demonstrating that the CQDs/Cu2O-based glucose sensor satisfies the requirements of complex sample detection with adapted potential for therapeutic diagnosticsLire moins >
Lire la suite >Perturbations in glucose homeostasis is critical for human health, as hyperglycemia (defining diabetes) leads to premature death caused by macrovascular and microvascular complications. However, the simple and accurate detection of glucose in the blood at low cost remains a challenging task, although it is of great importance for the diagnosis and therapy of diabetic patients. In this work, carbon quantum dots decorated with copper oxide nanostructures (CQDs/Cu2O) are prepared by a simple hydrothermal approach, and their potential for electrochemical non-enzymatic glucose sensing is evaluated. The proposed sensor exhibits excellent electrocatalytic activity towards glucose oxidation in alkaline solutions. The glucose sensor is characterized by a wide concentration range from 6 µM to 6 mM, a sensitivity of 2.9 ± 0.2 µA·µM−1·cm−2, and a detection limit of 6 µM at a signal-to-noise ratio S/N = 3. The sensors are successfully applied for glucose determination in human serum samples, demonstrating that the CQDs/Cu2O-based glucose sensor satisfies the requirements of complex sample detection with adapted potential for therapeutic diagnosticsLire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
ISEN
Univ. Valenciennes
ENSCL
CNRS
INRA
Institut Catholique Lille
Centrale Lille
ISEN
Univ. Valenciennes
ENSCL
CNRS
INRA
Institut Catholique Lille
Centrale Lille
Collections :
Date de dépôt :
2019-05-16T17:21:25Z
2022-11-09T10:59:56Z
2022-11-09T10:59:56Z
Fichiers
- sensors-16-01720.pdf
- Non spécifié
- Accès libre
- Accéder au document