Salvage reconstruction of hip ligaments ...
Type de document :
Compte-rendu et recension critique d'ouvrage
PMID :
Titre :
Salvage reconstruction of hip ligaments using absorbable material to treat recurrent instability of revision THA without abductor mechanism.
Auteur(s) :
Sarrazin, Jérémy [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Dartus, Julien [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Martinot, Pierre [Auteur]
Marrow Adiposity & Bone Lab - Adiposité Médullaire et Os - ULR 4490 [MABLab (ex-pmoi)]
Galmiche, Romain [Auteur]
CIC CHU ( Lille)/inserm
Migaud, Henri [Auteur]
Marrow Adiposity & Bone Lab - Adiposité Médullaire et Os - ULR 4490 [MABLab (ex-pmoi)]
Putman, Sophie [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Dartus, Julien [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Martinot, Pierre [Auteur]
Marrow Adiposity & Bone Lab - Adiposité Médullaire et Os - ULR 4490 [MABLab (ex-pmoi)]
Galmiche, Romain [Auteur]
CIC CHU ( Lille)/inserm
Migaud, Henri [Auteur]
Marrow Adiposity & Bone Lab - Adiposité Médullaire et Os - ULR 4490 [MABLab (ex-pmoi)]
Putman, Sophie [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Titre de la revue :
Orthopaedics & Traumatology: Surgery & Research
Pagination :
102783
Éditeur :
Elsevier
Date de publication :
2020-12-17
ISSN :
1877-0568
Mot(s)-clé(s) en anglais :
Total hip arthroplasty
Recurrent dislocation
Artificial ligament
Constrained liner
Ligament reconstruction
Polyglactin (Vicryl (TM))
Recurrent dislocation
Artificial ligament
Constrained liner
Ligament reconstruction
Polyglactin (Vicryl (TM))
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Dual-mobility and constrained cups can stabilise most recurrent dislocations of total hip arthroplasty (THA), but may fail in case of hip abductor mechanism loss. For such complex situations, we developed an original ...
Lire la suite >Dual-mobility and constrained cups can stabilise most recurrent dislocations of total hip arthroplasty (THA), but may fail in case of hip abductor mechanism loss. For such complex situations, we developed an original artificial iliofemoral and ischiofemoral ligament reconstruction technique using a polyglactin 910 mesh (Vicryl ™) associated to repositioning of a Lefèvre constrained liner adapted to hip range of motion to prevent cam effects. The technique was implemented in 2 patients showing recurrent dislocation after THA, associating total femur replacement and cemented constrained liner in a metal reinforcement ring. In one of the 2 cases, the abductor mechanism had been entirely sacrificed. This simple and accessible salvage technique prevented recurrence of dislocation at 12 months’ follow-up in these complex cases, previously subject to several episodes per year.Lire moins >
Lire la suite >Dual-mobility and constrained cups can stabilise most recurrent dislocations of total hip arthroplasty (THA), but may fail in case of hip abductor mechanism loss. For such complex situations, we developed an original artificial iliofemoral and ischiofemoral ligament reconstruction technique using a polyglactin 910 mesh (Vicryl ™) associated to repositioning of a Lefèvre constrained liner adapted to hip range of motion to prevent cam effects. The technique was implemented in 2 patients showing recurrent dislocation after THA, associating total femur replacement and cemented constrained liner in a metal reinforcement ring. In one of the 2 cases, the abductor mechanism had been entirely sacrificed. This simple and accessible salvage technique prevented recurrence of dislocation at 12 months’ follow-up in these complex cases, previously subject to several episodes per year.Lire moins >
Langue :
Anglais
Vulgarisation :
Non
Collections :
Source :
Fichiers
- j.otsr.2020.102783
- Accès libre