Evaluation of night-time aerosols measurements ...
Document type :
Article dans une revue scientifique: Article original
Permalink :
Title :
Evaluation of night-time aerosols measurements and lunar irradiance models in the frame of the first multi-instrument nocturnal intercomparison campaign
Author(s) :
Barreto, Africa [Auteur]
Agencia Estatal de Meteorología [AEMet]
Izaña Atmospheric Research Center [IARC]
Universidad de Valladolid [Valladolid] [UVa]
Roman, Roberto [Auteur]
Instituto Interuniversitario de Investigacion del Sistema Tierra en Andalucia [IISTA-CEAMA]
Universidad de Valladolid [Valladolid] [UVa]
Cuevas-Agullo, Emilio [Auteur]
Izaña Atmospheric Research Center [IARC]
Perez-Ramirez, Daniel [Auteur]
Instituto Interuniversitario de Investigacion del Sistema Tierra en Andalucia [IISTA-CEAMA]
Berjon, A. J. [Auteur]
Kouremeti, Natalia [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Kazadzis, Stelios [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Grobner, Julian [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Mazzola, M. [Auteur]
Istituto di Scienze dell'Atmosfera e del Clima [Bologna] [ISAC]
CNR Institute of Atmospheric Sciences and Climate [ISAC]
Toledano, Carlos [Auteur]
Benavent-Oltra, J. A. [Auteur]
Doppler, L. [Auteur]
Lindenberg Meteorological Observatory - Richard Assmann Observatory [MOL-RAO]
Jurysek, J. [Auteur]
Czech Academy of Sciences [Prague] [CAS]
Almansa, A. F. [Auteur]
Victori, Stephane [Auteur]
Maupin, F. [Auteur]
Guirado-Fuentes, C. [Auteur]
Gonzalez, Ramiro [Auteur]
Vitale, V. [Auteur]
Goloub, P. [Auteur]
Laboratoire d’Optique Atmosphérique - UMR 8518 [LOA]
Blarel, Luc [Auteur]
Laboratoire d’Optique Atmosphérique - UMR 8518 [LOA]
Alados-Arboledas, Lucas [Auteur]
Woolliams, E. [Auteur]
National Physical Laboratory [Teddington] [NPL]
Taylor, S. [Auteur]
Antuna, J. C. [Auteur]
Yela, M. [Auteur]
Instituto Nacional de Técnica Aeroespacial [INTA]
Agencia Estatal de Meteorología [AEMet]
Izaña Atmospheric Research Center [IARC]
Universidad de Valladolid [Valladolid] [UVa]
Roman, Roberto [Auteur]
Instituto Interuniversitario de Investigacion del Sistema Tierra en Andalucia [IISTA-CEAMA]
Universidad de Valladolid [Valladolid] [UVa]
Cuevas-Agullo, Emilio [Auteur]
Izaña Atmospheric Research Center [IARC]
Perez-Ramirez, Daniel [Auteur]
Instituto Interuniversitario de Investigacion del Sistema Tierra en Andalucia [IISTA-CEAMA]
Berjon, A. J. [Auteur]
Kouremeti, Natalia [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Kazadzis, Stelios [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Grobner, Julian [Auteur]
Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center [PMOD/WRC]
Mazzola, M. [Auteur]
Istituto di Scienze dell'Atmosfera e del Clima [Bologna] [ISAC]
CNR Institute of Atmospheric Sciences and Climate [ISAC]
Toledano, Carlos [Auteur]
Benavent-Oltra, J. A. [Auteur]
Doppler, L. [Auteur]
Lindenberg Meteorological Observatory - Richard Assmann Observatory [MOL-RAO]
Jurysek, J. [Auteur]
Czech Academy of Sciences [Prague] [CAS]
Almansa, A. F. [Auteur]
Victori, Stephane [Auteur]
Maupin, F. [Auteur]
Guirado-Fuentes, C. [Auteur]
Gonzalez, Ramiro [Auteur]
Vitale, V. [Auteur]
Goloub, P. [Auteur]
Laboratoire d’Optique Atmosphérique - UMR 8518 [LOA]
Blarel, Luc [Auteur]
Laboratoire d’Optique Atmosphérique - UMR 8518 [LOA]
Alados-Arboledas, Lucas [Auteur]
Woolliams, E. [Auteur]
National Physical Laboratory [Teddington] [NPL]
Taylor, S. [Auteur]
Antuna, J. C. [Auteur]
Yela, M. [Auteur]
Instituto Nacional de Técnica Aeroespacial [INTA]
Journal title :
Atmospheric Environment
Abbreviated title :
Atmos. Environ.
Volume number :
202
Publication date :
2019-04-01
ISSN :
1352-2310
English keyword(s) :
Lunar photometry
Star photometry
AOD
ROLO
Star photometry
AOD
ROLO
HAL domain(s) :
Physique [physics]
English abstract : [en]
The first multi-instrument nocturnal aerosol optical depth (AOD) intercomparison campaign was held at the high-mountain Izaña Observatory (Tenerife, Spain) in June 2017, involving 2-min synchronous measurements from two ...
Show more >The first multi-instrument nocturnal aerosol optical depth (AOD) intercomparison campaign was held at the high-mountain Izaña Observatory (Tenerife, Spain) in June 2017, involving 2-min synchronous measurements from two different types of lunar photometers (Cimel CE318-T and Moon Precision Filter Radiometer, LunarPFR) and one stellar photometer. The Robotic Lunar Observatory (ROLO) model developed by the U.S. Geological Survey (USGS) was compared with the open-access ROLO Implementation for Moon photometry Observation (RIMO) model. Results showed rather small differences at Izaña over a 2-month time period covering June and July, 2017 ( 0.01 in terms of AOD calculated by means of a day/night/day coherence test analysis and 2% in terms of lunar irradiance). The RIMO model has been used in this field campaign to retrieve AOD from lunar photometric measurements. No evidence of significant differences with the Moon's phase angle was found when comparing raw signals of the six Cimel photometers involved in this field campaign. The raw signal comparison of the participating lunar photometers (Cimel and LunarPFR) performed at coincident wavelengths showed consistent measurements and AOD differences within their combined uncertainties at 870 nm and 675 nm. Slightly larger AOD deviations were observed at 500 nm, pointing to some unexpected instrumental variations during the measurement period. Lunar irradiances retrieved using RIMO for phase angles varying between 0° and 75° (full Moon to near quarter Moon) were compared to the irradiance variations retrieved by Cimel and LunarPFR photometers. Our results showed a relative agreement within 3.5% between the RIMO model and the photometer-based lunar irradiances. The AOD retrieved by performing a Langley-plot calibration each night showed a remarkable agreement (better than 0.01) between the lunar photometers. However, when applying the Lunar-Langley calibration using RIMO, AOD differences of up to 0.015 (0.040 for 500 nm) were found, with differences increasing with the Moon's phase angle. These differences are thought to be partly due to the uncertainties in the irradiance models, as well as instrumental deficiencies yet to be fully understood. High AOD variability in stellar measurements was detected during the campaign. Nevertheless, the observed AOD differences in the Cimel/stellar comparison were within the expected combined uncertainties of these two photometric techniques. Our results indicate that lunar photometry is a more reliable technique, especially for low aerosol loading conditions. The uncertainty analysis performed in this paper shows that the combined standard AOD uncertainty in lunar photometry is dependent on the calibration technique (up to 0.014 for Langley-plot with illumination-based correction, 0.012–0.022 for Lunar-Langley calibration, and up to 0.1 for the Sun-Moon Gain Factor method). This analysis also corroborates that the uncertainty of the lunar irradiance model used for AOD calculation is within the 5–10% expected range. This campaign has allowed us to quantify the important technical difficulties that still exist when routinely monitoring aerosol optical properties at night-time. The small AOD differences observed between the three types of photometers involved in the campaign are only detectable under pristine sky conditions such as those found in this field campaign. Longer campaigns are necessary to understand the observed discrepancies between instruments as well as to provide more conclusive results about the uncertainty involved in the lunar irradiance models.Show less >
Show more >The first multi-instrument nocturnal aerosol optical depth (AOD) intercomparison campaign was held at the high-mountain Izaña Observatory (Tenerife, Spain) in June 2017, involving 2-min synchronous measurements from two different types of lunar photometers (Cimel CE318-T and Moon Precision Filter Radiometer, LunarPFR) and one stellar photometer. The Robotic Lunar Observatory (ROLO) model developed by the U.S. Geological Survey (USGS) was compared with the open-access ROLO Implementation for Moon photometry Observation (RIMO) model. Results showed rather small differences at Izaña over a 2-month time period covering June and July, 2017 ( 0.01 in terms of AOD calculated by means of a day/night/day coherence test analysis and 2% in terms of lunar irradiance). The RIMO model has been used in this field campaign to retrieve AOD from lunar photometric measurements. No evidence of significant differences with the Moon's phase angle was found when comparing raw signals of the six Cimel photometers involved in this field campaign. The raw signal comparison of the participating lunar photometers (Cimel and LunarPFR) performed at coincident wavelengths showed consistent measurements and AOD differences within their combined uncertainties at 870 nm and 675 nm. Slightly larger AOD deviations were observed at 500 nm, pointing to some unexpected instrumental variations during the measurement period. Lunar irradiances retrieved using RIMO for phase angles varying between 0° and 75° (full Moon to near quarter Moon) were compared to the irradiance variations retrieved by Cimel and LunarPFR photometers. Our results showed a relative agreement within 3.5% between the RIMO model and the photometer-based lunar irradiances. The AOD retrieved by performing a Langley-plot calibration each night showed a remarkable agreement (better than 0.01) between the lunar photometers. However, when applying the Lunar-Langley calibration using RIMO, AOD differences of up to 0.015 (0.040 for 500 nm) were found, with differences increasing with the Moon's phase angle. These differences are thought to be partly due to the uncertainties in the irradiance models, as well as instrumental deficiencies yet to be fully understood. High AOD variability in stellar measurements was detected during the campaign. Nevertheless, the observed AOD differences in the Cimel/stellar comparison were within the expected combined uncertainties of these two photometric techniques. Our results indicate that lunar photometry is a more reliable technique, especially for low aerosol loading conditions. The uncertainty analysis performed in this paper shows that the combined standard AOD uncertainty in lunar photometry is dependent on the calibration technique (up to 0.014 for Langley-plot with illumination-based correction, 0.012–0.022 for Lunar-Langley calibration, and up to 0.1 for the Sun-Moon Gain Factor method). This analysis also corroborates that the uncertainty of the lunar irradiance model used for AOD calculation is within the 5–10% expected range. This campaign has allowed us to quantify the important technical difficulties that still exist when routinely monitoring aerosol optical properties at night-time. The small AOD differences observed between the three types of photometers involved in the campaign are only detectable under pristine sky conditions such as those found in this field campaign. Longer campaigns are necessary to understand the observed discrepancies between instruments as well as to provide more conclusive results about the uncertainty involved in the lunar irradiance models.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CNRS
Université de Lille
Université de Lille
Collections :
Submission date :
2024-01-30T11:45:51Z
2024-02-27T08:15:15Z
2024-02-27T08:15:15Z
Files
- 1-s2.0-S1352231019300287-mainext.pdf
- Version éditeur
- Open access
- Access the document