Pulmonary valve replacement in a large and ...
  • BibTeX
  • CSV
  • Excel
  • RIS

Document type :
Article dans une revue scientifique: Article original
DOI :
10.1093/ehjcr/ytad322
Title :
Pulmonary valve replacement in a large and tortuous right ventricle outflow tract with a 32 mm Myval valve under local anaesthesia: challenges and technical considerations: a case report
Author(s) :
Houeijeh, Ali [Auteur]
Sudre, Arnaud [Auteur]
Juthier, Francis [Auteur] refId
Récepteurs Nucléaires, Maladies Métaboliques et Cardiovasculaires - U 1011 [RNMCD]
Godart, François [Auteur]
Journal title :
European Heart Journal. Case Reports
Publisher :
Oxford University Press
Publication date :
2023-08-01
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
Abstract Background Pulmonary valve replacement in patients with congenital heart diseases and heart failure is challenging. Case summary Here, we describe a case of a patient who had surgical fallot repair with chronic ...
Show more >
Abstract Background Pulmonary valve replacement in patients with congenital heart diseases and heart failure is challenging. Case summary Here, we describe a case of a patient who had surgical fallot repair with chronic heart failure. Investigations found severe biventricular dysfunction and enlargement due to chronic pulmonary regurgitation. The right ventricle outflow tract was tortuous and large with a diameter of 35 mm. Percutaneous pulmonary valve implantation (PPVI) was done after a challenging pre-stenting. A 32 mm Myval valve over-sized to 35 mm was used for PPVI, which yielded a good result. Discussion A 32 mm Myval valve is effective at extending the possibilities of PPVI in a large and tortuous right ventricle outflow tract not accessible for the other valves.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Collections :
  • Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (RNMCD) - U1011
Source :
Harvested from HAL
Files
Thumbnail
  • ytad322.pdf
  • Open access
  • Access the document
Université de Lille

Mentions légales
Accessibilité : non conforme
Université de Lille © 2017