Insights from Nitrogen Compounds in Gas ...
Document type :
Article dans une revue scientifique: Article original
Permalink :
Title :
Insights from Nitrogen Compounds in Gas Oils Highlighted by High-Resolution Fourier Transform Mass Spectrometry
Author(s) :
Guillemant, Julie [Auteur]
IFP Energies nouvelles [IFPEN]
Albrieux, Florian [Auteur]
IFP Energies nouvelles [IFPEN]
de Oliveira, Luis Pereira [Auteur]
IFP Energies nouvelles [IFPEN]
Lacoue-Nègre, Marion [Auteur]
IFP Energies nouvelles [IFPEN]
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Joly, Jean-François [Auteur]
IFP Energies nouvelles [IFPEN]
IFP Energies nouvelles [IFPEN]
Albrieux, Florian [Auteur]
IFP Energies nouvelles [IFPEN]
de Oliveira, Luis Pereira [Auteur]
IFP Energies nouvelles [IFPEN]
Lacoue-Nègre, Marion [Auteur]
IFP Energies nouvelles [IFPEN]
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Joly, Jean-François [Auteur]
IFP Energies nouvelles [IFPEN]
Journal title :
Analytical Chemistry
Volume number :
91
Pages :
12644-12652
Publication date :
2019
HAL domain(s) :
Chimie/Chimie théorique et/ou physique
English abstract : [en]
Twenty-three gas oil samples from different origins were analyzed in positive and negative ion modes by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI(±)-FT-ICR MS). Sample ionization ...
Show more >Twenty-three gas oil samples from different origins were analyzed in positive and negative ion modes by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI(±)-FT-ICR MS). Sample ionization and ion transfer conditions were first optimized using Design of Experiment approach. Advanced characterization of basic and neutral nitrogen compounds in these samples was then performed through ESI(±)-FT-ICR MS analysis. A good repeatability was observed from the analysis of six replicates for each gas oil sample. Significant differences in molecular composition were spotted between the gas oils, either considering identified heteroatomic classes or within nitrogen families and were later correlated to samples macroscopic properties. The evolution of nitrogen relative intensities for one feed and two corresponding effluents has also been studied to monitor hydrotreatment reaction pathways toward aromaticity and alkylation levels evolutions.Show less >
Show more >Twenty-three gas oil samples from different origins were analyzed in positive and negative ion modes by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI(±)-FT-ICR MS). Sample ionization and ion transfer conditions were first optimized using Design of Experiment approach. Advanced characterization of basic and neutral nitrogen compounds in these samples was then performed through ESI(±)-FT-ICR MS analysis. A good repeatability was observed from the analysis of six replicates for each gas oil sample. Significant differences in molecular composition were spotted between the gas oils, either considering identified heteroatomic classes or within nitrogen families and were later correlated to samples macroscopic properties. The evolution of nitrogen relative intensities for one feed and two corresponding effluents has also been studied to monitor hydrotreatment reaction pathways toward aromaticity and alkylation levels evolutions.Show less >
Audience :
Non spécifiée
Popular science :
Non
Administrative institution(s) :
ENSCL
CNRS
Université de Lille
CNRS
Université de Lille
Collections :
Research team(s) :
Propriétés magnéto structurales des matériaux (PMSM)
Submission date :
2024-02-21T17:12:05Z
2024-02-23T11:46:45Z
2024-02-23T11:46:45Z
Files
- document
- Open access
- Access the document