Evaluation of outcomes in renal transplantation ...
Document type :
Article dans une revue scientifique: Article original
DOI :
PMID :
Permalink :
Title :
Evaluation of outcomes in renal transplantation with hypothermic machine perfusion for the preservation of kidneys from expanded-criteria donors.
Author(s) :
Savoye, Emilie [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Macher, Marie-Alice [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Videcoq, Michel [Auteur]
Centre Hospitalier Universitaire de Nantes = Nantes University Hospital [CHU Nantes]
Gatault, Philippe [Auteur]
Hazzan, Marc [Auteur]
Lille Inflammation Research International Center - U 995 [LIRIC]
Abboud, Imad [Auteur]
Hopital Saint-Louis [AP-HP] [AP-HP]
Thierry, Antoine [Auteur]
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Bertrand, Dominique [Auteur]
CHU Rouen
Drouin, Sarah [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Sayegh, Johnny [Auteur]
Centre Hospitalier Universitaire d'Angers [CHU Angers]
Barrou, Benoit [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Badet, Lionel [Auteur]
Hospices Civils de Lyon [HCL]
Bastien, Olivier [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Lamotte, Christian [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Logerot, Helene [Auteur]
Legeai, Camille [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Antoine, Corinne [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Agence de la biomédecine [Saint-Denis la Plaine]
Macher, Marie-Alice [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Videcoq, Michel [Auteur]
Centre Hospitalier Universitaire de Nantes = Nantes University Hospital [CHU Nantes]
Gatault, Philippe [Auteur]
Hazzan, Marc [Auteur]
Lille Inflammation Research International Center - U 995 [LIRIC]
Abboud, Imad [Auteur]
Hopital Saint-Louis [AP-HP] [AP-HP]
Thierry, Antoine [Auteur]
Centre hospitalier universitaire de Poitiers = Poitiers University Hospital [CHU de Poitiers [La Milétrie]]
Bertrand, Dominique [Auteur]
CHU Rouen
Drouin, Sarah [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Sayegh, Johnny [Auteur]
Centre Hospitalier Universitaire d'Angers [CHU Angers]
Barrou, Benoit [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Badet, Lionel [Auteur]
Hospices Civils de Lyon [HCL]
Bastien, Olivier [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Lamotte, Christian [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Logerot, Helene [Auteur]
Legeai, Camille [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Antoine, Corinne [Auteur]
Agence de la biomédecine [Saint-Denis la Plaine]
Journal title :
Clinical Transplantation
Abbreviated title :
Clin Transplant
Volume number :
33
Pages :
e13536
Publication date :
2019-05
ISSN :
1399-0012
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
In 2012, an expert working group from the French Transplant Health Authority recommended the use of hypothermic machine perfusion (HMP) to improve kidney preservation and transplant outcomes from expanded criteria donors, ...
Show more >In 2012, an expert working group from the French Transplant Health Authority recommended the use of hypothermic machine perfusion (HMP) to improve kidney preservation and transplant outcomes from expanded criteria donors, deceased after brain death. This study compares HMP and cold storage (CS) effects on delayed graft function (DGF) and transplant outcomes. We identified 4,316 kidney transplants from expanded criteria donors (2011-2014) in France through the French Transplant Registry. DGF occurrence was analyzed with a logistic regression, excluding preemptive transplants. One-year graft failure was analyzed with a Cox regression. A subpopulation of 66 paired kidneys was identified: one preserved by HMP and the other by CS from the same donor. Kidneys preserved by HMP (801) vs CS (3515) were associated with more frequent recipient comorbidities and older donors and recipients. HMP had a protective effect against DGF (24% in HMP group and 38% in CS group, OR = 0.49 [0.40-0.60]). Results were similar in the paired kidneys (OR = 0.23 [0.04-0.57]). HMP use decreased risk for 1-year graft failure (HR = 0.77 [0.60-0.99]). Initial hospital stays were shorter in the HMP group (P < 0.001). Our results confirm the reduction in DGF occurrence among expanded criteria donors kidneys preserved by HMP.Show less >
Show more >In 2012, an expert working group from the French Transplant Health Authority recommended the use of hypothermic machine perfusion (HMP) to improve kidney preservation and transplant outcomes from expanded criteria donors, deceased after brain death. This study compares HMP and cold storage (CS) effects on delayed graft function (DGF) and transplant outcomes. We identified 4,316 kidney transplants from expanded criteria donors (2011-2014) in France through the French Transplant Registry. DGF occurrence was analyzed with a logistic regression, excluding preemptive transplants. One-year graft failure was analyzed with a Cox regression. A subpopulation of 66 paired kidneys was identified: one preserved by HMP and the other by CS from the same donor. Kidneys preserved by HMP (801) vs CS (3515) were associated with more frequent recipient comorbidities and older donors and recipients. HMP had a protective effect against DGF (24% in HMP group and 38% in CS group, OR = 0.49 [0.40-0.60]). Results were similar in the paired kidneys (OR = 0.23 [0.04-0.57]). HMP use decreased risk for 1-year graft failure (HR = 0.77 [0.60-0.99]). Initial hospital stays were shorter in the HMP group (P < 0.001). Our results confirm the reduction in DGF occurrence among expanded criteria donors kidneys preserved by HMP.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CHU Lille
Inserm
Université de Lille
Inserm
Université de Lille
Submission date :
2019-10-22T07:44:33Z
2024-04-29T13:13:31Z
2024-04-29T13:13:31Z