Advanced image processing with fusion and calcification enhancement in transcatheter aortic valve implantation: impact on radiation exposure
Author(s) :
Overtchouk, Pavel [Auteur]
Sudre, Arnaud [Auteur]
Delhaye, Cédric [Auteur]
Juthier, Francis [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (EGID) - U1011
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (RNMCD) - U1011
Van Belle, Eric [Auteur]
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (EGID) - U1011
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (RNMCD) - U1011
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Coisne, Augustin [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Koussa, Mohamad [Auteur]
Mylotte, Darren [Auteur]
Modine, Thomas [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Sudre, Arnaud [Auteur]
Delhaye, Cédric [Auteur]
Juthier, Francis [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (EGID) - U1011
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (RNMCD) - U1011
Van Belle, Eric [Auteur]
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (EGID) - U1011
Récepteurs nucléaires, Maladies Cardiovasculaires et Diabète (RNMCD) - U1011
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Coisne, Augustin [Auteur]
Récepteurs nucléaires, maladies cardiovasculaires et diabète - U 1011 [RNMCD]
Koussa, Mohamad [Auteur]
Mylotte, Darren [Auteur]
Modine, Thomas [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Journal title :
Interactive cardiovascular and thoracic surgery
Abbreviated title :
Interact Cardiovasc Thorac Surg
Publication date :
2018-04-23
ISSN :
1569-9285
English keyword(s) :
Multislice computed tomography
Radiation protection
Transcatheter aortic valve implantation
Radiation
Transcatheter aortic valve replacement
Radiation protection
Transcatheter aortic valve implantation
Radiation
Transcatheter aortic valve replacement
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
Radiation exposure is a concern for both patients and operators during transcatheter aortic valve implantation (TAVI). Efforts to reduce radiation dose are warranted. We aimed at investigating if per-operative advanced ...
Show more >Radiation exposure is a concern for both patients and operators during transcatheter aortic valve implantation (TAVI). Efforts to reduce radiation dose are warranted. We aimed at investigating if per-operative advanced image processing can reduce patient and operator irradiation use during TAVI. We performed a prospective single-centre observational study comparing patient and operator radiation exposure using standard fluoroscopy (control group) or a novel technology of live advanced fluoroscopic image processing (test group) among consecutive patients undergoing TAVI between August 2015 and April 2016. Patient irradiation (dose-area product, effective dose and air kerma), contrast media volume and clinical outcomes were assessed. Among 152 elderly [median age (interquartile range): 83 (78-87)] patients (n = 76 per group) undergoing TAVI, baseline clinical characteristics were similar between the control and test groups, except for a higher median EuroSCORE II (2.8% vs 2.3%, P = 0.02) and higher rate of TAVI for failing surgical bioprosthesis (11.8% vs 2.6%, P = 0.03) in the control group. The dose-area product was reduced in the test group: mean reduction of -27.5 Gy × cm2 [95% confidence intervals (CIs): 15.9-39.1, P < 0.001]. Furthermore, effective dose [mean reduction -6.5 (95% CI: 5.9-7.2) mSv, P < 0.001] and air kerma [mean reduction -167.5 (95% CI 163.4-177.3) mGy, P < 0.001] were lower in the test group. Fluoroscopy time, contrast volume and clinical outcomes were similar. Patient radiation exposure was significantly reduced using a novel live advanced fluoroscopy image processing with calcification enhancement and fusion of the virtual aortic annulus without compromising patient safety.Show less >
Show more >Radiation exposure is a concern for both patients and operators during transcatheter aortic valve implantation (TAVI). Efforts to reduce radiation dose are warranted. We aimed at investigating if per-operative advanced image processing can reduce patient and operator irradiation use during TAVI. We performed a prospective single-centre observational study comparing patient and operator radiation exposure using standard fluoroscopy (control group) or a novel technology of live advanced fluoroscopic image processing (test group) among consecutive patients undergoing TAVI between August 2015 and April 2016. Patient irradiation (dose-area product, effective dose and air kerma), contrast media volume and clinical outcomes were assessed. Among 152 elderly [median age (interquartile range): 83 (78-87)] patients (n = 76 per group) undergoing TAVI, baseline clinical characteristics were similar between the control and test groups, except for a higher median EuroSCORE II (2.8% vs 2.3%, P = 0.02) and higher rate of TAVI for failing surgical bioprosthesis (11.8% vs 2.6%, P = 0.03) in the control group. The dose-area product was reduced in the test group: mean reduction of -27.5 Gy × cm2 [95% confidence intervals (CIs): 15.9-39.1, P < 0.001]. Furthermore, effective dose [mean reduction -6.5 (95% CI: 5.9-7.2) mSv, P < 0.001] and air kerma [mean reduction -167.5 (95% CI 163.4-177.3) mGy, P < 0.001] were lower in the test group. Fluoroscopy time, contrast volume and clinical outcomes were similar. Patient radiation exposure was significantly reduced using a novel live advanced fluoroscopy image processing with calcification enhancement and fusion of the virtual aortic annulus without compromising patient safety.Show less >