First-in-man study of heartech� percutaneous ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
PMID :
URL permanente :
Titre :
First-in-man study of heartech� percutaneous left ventricular partitioning device for treatment of heart failure postmyocardial infarction
Auteur(s) :
Zhu, Zhengbin [Auteur]
Yu, Jiwei [Auteur]
Xu, Kai [Auteur]
Tang, Yimin [Auteur]
Fang, Yuehua [Auteur]
Gu, Jianing [Auteur]
Gu, Shengjia [Auteur]
Ding, Fenghua [Auteur]
Modine, Thomas [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Zhang, Ruiyan [Auteur]
Yu, Jiwei [Auteur]
Xu, Kai [Auteur]
Tang, Yimin [Auteur]
Fang, Yuehua [Auteur]
Gu, Jianing [Auteur]
Gu, Shengjia [Auteur]
Ding, Fenghua [Auteur]
Modine, Thomas [Auteur]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U 1171 - EA 1046 [TCDV]
Troubles cognitifs dégénératifs et vasculaires - U1171
Zhang, Ruiyan [Auteur]
Titre de la revue :
Catheterization and cardiovascular interventions . official journal of the Society for Cardiac Angiography & Interventions
Nom court de la revue :
Catheter Cardiovasc Interv
Date de publication :
2019-06-23
ISSN :
1522-726X
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
OBJECTIVE: This first-in-man (FIM) study aimed to determine the safety and efficacy of the Heartech® left ventricular partitioning device (LVPD) in patients with chronic heart failure (HF) postmyocardial infarction.
METHODS: ...
Lire la suite >OBJECTIVE: This first-in-man (FIM) study aimed to determine the safety and efficacy of the Heartech® left ventricular partitioning device (LVPD) in patients with chronic heart failure (HF) postmyocardial infarction. METHODS: Sixteen patients were enrolled from three cardiac intervention centers in China. All patients underwent percutaneous ventricular restoration (PVR) procedures with implantation of the Heartech® LVPD. Safety and immediate success rates were recorded. Major adverse cardiovascular and cerebrovascular events (MACCEs) including all-cause mortality, myocardial infarction, stroke, emergent or selective surgery or interventional therapy, renal failure requiring hemodialysis, and major bleeding were recorded. Efficacy features included functional status, echocardiographic characteristics, life quality characteristics including peak oxygen consumption of cardiopulmonary exercise testing (CPET), European five-dimensional health scale (EQ-5D), 6-min walk test (6MWT) at baseline and during follow-up (NCT02938637). RESULTS: The device success rate was 93.75% (15 successes in 16 patients) with 100% safety. During follow-up of 36 ± 4.5 days, no MACCEs were found. The left ventricular end-systolic volume index decreased significantly (LVESVi, 72.47 ± 22.77 mL/m2222 CONCLUSIONS: Heartech® LVPD appeared to be safe and effective for treatment of HF postmyocardial infarction.Lire moins >
Lire la suite >OBJECTIVE: This first-in-man (FIM) study aimed to determine the safety and efficacy of the Heartech® left ventricular partitioning device (LVPD) in patients with chronic heart failure (HF) postmyocardial infarction. METHODS: Sixteen patients were enrolled from three cardiac intervention centers in China. All patients underwent percutaneous ventricular restoration (PVR) procedures with implantation of the Heartech® LVPD. Safety and immediate success rates were recorded. Major adverse cardiovascular and cerebrovascular events (MACCEs) including all-cause mortality, myocardial infarction, stroke, emergent or selective surgery or interventional therapy, renal failure requiring hemodialysis, and major bleeding were recorded. Efficacy features included functional status, echocardiographic characteristics, life quality characteristics including peak oxygen consumption of cardiopulmonary exercise testing (CPET), European five-dimensional health scale (EQ-5D), 6-min walk test (6MWT) at baseline and during follow-up (NCT02938637). RESULTS: The device success rate was 93.75% (15 successes in 16 patients) with 100% safety. During follow-up of 36 ± 4.5 days, no MACCEs were found. The left ventricular end-systolic volume index decreased significantly (LVESVi, 72.47 ± 22.77 mL/m2222 CONCLUSIONS: Heartech® LVPD appeared to be safe and effective for treatment of HF postmyocardial infarction.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
CNRS
Inserm
Université de Lille
CNRS
Inserm
Université de Lille
Collections :
Équipe(s) de recherche :
Troubles cognitifs dégénératifs et vasculaires
Date de dépôt :
2019-11-27T13:36:10Z