Influence of ecg sampling rate in fetal ...
Type de document :
Article dans une revue scientifique: Article original
PMID :
URL permanente :
Titre :
Influence of ecg sampling rate in fetal heart rate variability analysis
Auteur(s) :
De Jonckheere, Julien [Auteur]
Centre d'Investigation Clinique - Innovation Technologique de Lille - CIC 1403 - CIC 9301 [CIC Lille]
Garabedian, Charles [Auteur]
Charlier, P. [Auteur]
Champion, C. [Auteur]
Servan-Schreiber, Elie [Auteur]
Storme, Laurent [Auteur]
Environnement périnatal et croissance - EA 4489 [EPS]
Environnement périnatal et croissance - EA 4489 [EPS]
Environnement Périnatal et Santé - EA 4489
Debarge, Veronique [Auteur]
Environnement Périnatal et Santé - EA 4489
Jeanne, Mathieu [Auteur]
Logier, Regis [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Centre d'Investigation Clinique - Innovation Technologique de Lille - CIC 1403 - CIC 9301 [CIC Lille]
Garabedian, Charles [Auteur]
Charlier, P. [Auteur]
Champion, C. [Auteur]
Servan-Schreiber, Elie [Auteur]
Storme, Laurent [Auteur]
Environnement périnatal et croissance - EA 4489 [EPS]
Environnement périnatal et croissance - EA 4489 [EPS]
Environnement Périnatal et Santé - EA 4489
Debarge, Veronique [Auteur]
Environnement Périnatal et Santé - EA 4489
Jeanne, Mathieu [Auteur]
Logier, Regis [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Titre de la revue :
Conference proceedings . ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
Nom court de la revue :
Conf Proc IEEE Eng Med Biol Soc
Numéro :
2017
Pagination :
2027-2030
Date de publication :
2017-07-01
ISSN :
1557-170X
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in ...
Lire la suite >Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).Lire moins >
Lire la suite >Fetal hypoxia results in a fetal blood acidosis (pH<;7.10). In such a situation, the fetus develops several adaptation mechanisms regulated by the autonomic nervous system. Many studies demonstrated significant changes in heart rate variability in hypoxic fetuses. So, fetal heart rate variability analysis could be of precious help for fetal hypoxia prediction. Commonly used fetal heart rate variability analysis methods have been shown to be sensitive to the ECG signal sampling rate. Indeed, a low sampling rate could induce variability in the heart beat detection which will alter the heart rate variability estimation. In this paper, we introduce an original fetal heart rate variability analysis method. We hypothesize that this method will be less sensitive to ECG sampling frequency changes than common heart rate variability analysis methods. We then compared the results of this new heart rate variability analysis method with two different sampling frequencies (250-1000 Hz).Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
Université de Lille
Université de Lille
Collections :
Date de dépôt :
2019-12-09T16:55:30Z
2021-05-14T09:06:24Z
2021-05-14T09:06:24Z