Inter-day test–retest reliability and ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
PMID :
URL permanente :
Titre :
Inter-day test–retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study
Auteur(s) :
Frykholm, Erik [Auteur]
Gephine, Sarah [Auteur]
Saey, Didier [Auteur]
Van Hees, Hieronymus [Auteur]
Radboud University Medical Center [Nijmegen]
Lemson, Arthur [Auteur]
Radboud University Medical Center [Nijmegen]
Klijn, Peter [Auteur]
VU University Medical Center [Amsterdam]
Maltais, François [Auteur]
Nyberg, André [Auteur]
Gephine, Sarah [Auteur]
Saey, Didier [Auteur]
Van Hees, Hieronymus [Auteur]
Radboud University Medical Center [Nijmegen]
Lemson, Arthur [Auteur]
Radboud University Medical Center [Nijmegen]
Klijn, Peter [Auteur]
VU University Medical Center [Amsterdam]
Maltais, François [Auteur]
Nyberg, André [Auteur]
Titre de la revue :
Chronic respiratory disease
Nom court de la revue :
Chron Respir Dis
Numéro :
16
Pagination :
1-9
Éditeur :
London : SAGE Publications
Date de publication :
2018-10
ISSN :
1479-9723
Mot(s)-clé(s) en anglais :
COPD; Intra-rater agreement; leg extension; lower limb muscle endurance; reproducibility
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
The aims were to determine reliability and feasibility of measurements to assess quadriceps endurance in people withchronicobstructive pulmonary disease.Sixty participants(forcedexpiratoryvolumein one second(mean+ standard ...
Lire la suite >The aims were to determine reliability and feasibility of measurements to assess quadriceps endurance in people withchronicobstructive pulmonary disease.Sixty participants(forcedexpiratoryvolumein one second(mean+ standard deviation) 55 + 18% of predicted, age 67 + 8 years) were tested in an inter-day, test–retest design. Isokinetic, isometric, and isotonic protocols were performed using a computerized dynamometer. Test–retest relative and absolute reliability was determined via intraclass correlation coefficient (ICC), coefficient of variation (CV%), and limits of agreement (LoA%). Isokinetic total work demonstrated very high relative reliability (ICC: [95% confidence interval] ¼ 0.98 [0.94–0.99]) and the best absolute reliability (CV% (LoA%) ¼ 6.5% (18.0%)). Isokinetic fatigue index, isometric, and isotonic measures demonstrated low-to-high relative reliability (ICC ¼ 0.64 [0.46–0.77], 0.88 [0.76–0.94], 0.91 [0.85–0.94]), and measures of absolute reliability (CV% (LoA%)) were 20.3% (56.4%), 14.9% (40.8%), and 15.8% (43.1%). For isokinetic total work and isometric measurements, participants performed better on retest (4.8% and 10.0%, respectively). The feasibility was similar across protocols with an average time consumption of less than 7.5 minutes. In conclusion, isokinetic, isometric, and isotonic measurements ofquadriceps endurance were feasible toa similar extent and presented low-to-very high relative reliability. Absolute reliability seems to favor isokinetic total work measurements.Lire moins >
Lire la suite >The aims were to determine reliability and feasibility of measurements to assess quadriceps endurance in people withchronicobstructive pulmonary disease.Sixty participants(forcedexpiratoryvolumein one second(mean+ standard deviation) 55 + 18% of predicted, age 67 + 8 years) were tested in an inter-day, test–retest design. Isokinetic, isometric, and isotonic protocols were performed using a computerized dynamometer. Test–retest relative and absolute reliability was determined via intraclass correlation coefficient (ICC), coefficient of variation (CV%), and limits of agreement (LoA%). Isokinetic total work demonstrated very high relative reliability (ICC: [95% confidence interval] ¼ 0.98 [0.94–0.99]) and the best absolute reliability (CV% (LoA%) ¼ 6.5% (18.0%)). Isokinetic fatigue index, isometric, and isotonic measures demonstrated low-to-high relative reliability (ICC ¼ 0.64 [0.46–0.77], 0.88 [0.76–0.94], 0.91 [0.85–0.94]), and measures of absolute reliability (CV% (LoA%)) were 20.3% (56.4%), 14.9% (40.8%), and 15.8% (43.1%). For isokinetic total work and isometric measurements, participants performed better on retest (4.8% and 10.0%, respectively). The feasibility was similar across protocols with an average time consumption of less than 7.5 minutes. In conclusion, isokinetic, isometric, and isotonic measurements ofquadriceps endurance were feasible toa similar extent and presented low-to-very high relative reliability. Absolute reliability seems to favor isokinetic total work measurements.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Non spécifiée
Établissement(s) :
Université de Lille
Univ. Artois
Univ. Littoral Côte d’Opale
Univ. Artois
Univ. Littoral Côte d’Opale
Collections :
Équipe(s) de recherche :
Activité Physique, Muscle, Santé (APMS)
Date de dépôt :
2020-04-01T16:44:57Z
2020-04-03T08:32:59Z
2020-04-03T08:34:58Z
2020-04-03T08:32:59Z
2020-04-03T08:34:58Z
Fichiers
- Articles-RFEQ-publié-CRD-2018.pdf
- Version éditeur
- Accès libre
- Accéder au document