An Overview of Methods using Reduced-Ordered ...
Type de document :
Communication dans un congrès avec actes
URL permanente :
Titre :
An Overview of Methods using Reduced-Ordered Transformation Matrices for Fault-Tolerant Control of 5-phase Machines with an Open Phase
Auteur(s) :
Vu, Duc-Tan [Auteur]
Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
Nguyen, Ngac-Ky [Auteur]
Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
semail, eric [Auteur]
Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697

Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
Nguyen, Ngac-Ky [Auteur]

Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
semail, eric [Auteur]

Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
Titre de la manifestation scientifique :
20th IEEE International Conference on Industrial Technology (ICIT 2019)
Ville :
Melbourne
Pays :
Australie
Date de début de la manifestation scientifique :
2019-02-13
Titre de l’ouvrage :
The 20th IEEE International Conference on Industrial Technology
Éditeur :
IEEE
Mot(s)-clé(s) en anglais :
Reduced-order transformation mactrices
5-phase machines
Open-phase faults
Fault-tolerant control
Back-EMF waveform
Current references
Torque control
5-phase machines
Open-phase faults
Fault-tolerant control
Back-EMF waveform
Current references
Torque control
Discipline(s) HAL :
Informatique [cs]/Systèmes et contrôle [cs.SY]
Sciences de l'ingénieur [physics]/Energie électrique
Sciences de l'ingénieur [physics]/Energie électrique
Résumé en anglais : [en]
This paper studies control strategies using modified transformation matrices when five-phase machines operate in one-open-phase faults. The basic idea of these methods is to maintain the rotating field under asymmetrical ...
Lire la suite >This paper studies control strategies using modified transformation matrices when five-phase machines operate in one-open-phase faults. The basic idea of these methods is to maintain the rotating field under asymmetrical conditions as the same as in healthy condition by determining new transformation matrices. The dimension of the new matrices is equal to the number of remaining healthy phases in post-fault conditions. There have been different ways to determine the new transformation matrices applied for different types of five-phase machines in recent decades. In this study, an overview and analyses on these methods will be presented. In addition, advantages and drawbacks of these control strategies are clarified by numerical results.Lire moins >
Lire la suite >This paper studies control strategies using modified transformation matrices when five-phase machines operate in one-open-phase faults. The basic idea of these methods is to maintain the rotating field under asymmetrical conditions as the same as in healthy condition by determining new transformation matrices. The dimension of the new matrices is equal to the number of remaining healthy phases in post-fault conditions. There have been different ways to determine the new transformation matrices applied for different types of five-phase machines in recent decades. In this study, an overview and analyses on these methods will be presented. In addition, advantages and drawbacks of these control strategies are clarified by numerical results.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Équipe(s) de recherche :
Équipe Commande
Date de dépôt :
2020-05-15T13:07:59Z
2022-03-10T12:49:23Z
2022-03-10T12:49:23Z
Fichiers
- https://hal.archives-ouvertes.fr/hal-02142425/document
- Accès libre
- Accéder au document