Fault Tolerant Multiphase Electrical Drives: ...
Document type :
Article dans une revue scientifique
DOI :
Permalink :
Title :
Fault Tolerant Multiphase Electrical Drives: The Impact of Design
Author(s) :
semail, eric [Auteur]
Arts et Métiers Sciences et Technologies
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Kestelyn, Xavier [Auteur]
13338|||Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Locment, Fabrice [Auteur]
13338|||Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

Arts et Métiers Sciences et Technologies
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Kestelyn, Xavier [Auteur]

13338|||Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Locment, Fabrice [Auteur]
13338|||Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Journal title :
European Physical Journal: Applied Physics
Volume number :
43
Pages :
159-163
Publisher :
EDP Sciences
Publication date :
2008-08
ISSN :
1286-0042
English keyword(s) :
Multiphase machine
Fault tolerance
design
Synchronous machine
Axial Flux machine
Fault tolerance
design
Synchronous machine
Axial Flux machine
HAL domain(s) :
Sciences de l'ingénieur [physics]/Automatique / Robotique
Sciences de l'ingénieur [physics]/Electromagnétisme
Sciences de l'ingénieur [physics]/Energie électrique
Sciences de l'ingénieur [physics]/Electromagnétisme
Sciences de l'ingénieur [physics]/Energie électrique
English abstract : [en]
This paper deals with fault tolerant multiphase electrical drives. The quality of the torque of a vector-controlled Permanent Magnet (PM) Synchronous Machine supplied by a multi-leg Voltage Source Inverter (VSI) is examined ...
Show more >This paper deals with fault tolerant multiphase electrical drives. The quality of the torque of a vector-controlled Permanent Magnet (PM) Synchronous Machine supplied by a multi-leg Voltage Source Inverter (VSI) is examined in normal operation and when one or two phases are open-circuited. It is then deduced that a seven-phase machine is a good compromise allowing high torque-to-volume density and easy control with smooth torque in fault operation. Experimental results confirm the predicted characteristics.Show less >
Show more >This paper deals with fault tolerant multiphase electrical drives. The quality of the torque of a vector-controlled Permanent Magnet (PM) Synchronous Machine supplied by a multi-leg Voltage Source Inverter (VSI) is examined in normal operation and when one or two phases are open-circuited. It is then deduced that a seven-phase machine is a good compromise allowing high torque-to-volume density and easy control with smooth torque in fault operation. Experimental results confirm the predicted characteristics.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Comment :
La version editeur de cet article est disponible à l'adresse suivante : http://journals.cambridge.org/action//displayFulltext?type=1&fid=8024174&jid=JAP&volumeId=43&issueId=02&aid=8024172&bodyId=&membershipNumber=&societyETOCSession=
Research team(s) :
Équipe Commande
Équipe Réseaux
Équipe Réseaux
Submission date :
2020-05-15T14:51:51Z
2022-03-16T13:57:34Z
2022-03-16T13:57:34Z
Files
- https://hal.archives-ouvertes.fr/hal-00819009/document
- Open access
- Access the document
- https://www.epjap.org/articles/epjap/pdf/2008/08/ap07226.pdf
- Open access
- Access the document