A study of rotating stall in a vaneless ...
Document type :
Compte-rendu et recension critique d'ouvrage
Title :
A study of rotating stall in a vaneless diffuser of radial flow pump
Author(s) :
Heng, Yaguang [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Dazin, Antoine [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Ouarzazi, Mohamed Najib [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Si, Qiaorui [Auteur]
JiangSu University
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Dazin, Antoine [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Ouarzazi, Mohamed Najib [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Si, Qiaorui [Auteur]
JiangSu University
Journal title :
Journal of Hydraulic Research
Pages :
494-504
Publisher :
Taylor & Francis
Publication date :
2018
ISSN :
0022-1686
English keyword(s) :
Rotating stall
Vaneless diffuser
Radial flow pump or compressor
Vaneless diffuser
Radial flow pump or compressor
HAL domain(s) :
Sciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Mécanique des fluides [physics.class-ph]
English abstract : [en]
Rotating stall in a vaneless diffuser of radial flow pump is studied. The measurements consist of: (i) unsteady pressure measurements delivered by two microphones; and (ii) nine steady pressure taps mounted in one radial ...
Show more >Rotating stall in a vaneless diffuser of radial flow pump is studied. The measurements consist of: (i) unsteady pressure measurements delivered by two microphones; and (ii) nine steady pressure taps mounted in one radial line to measure the pressure recovery in the vaneless diffuser. Spectrum analysis was used to identify and characterize rotating stall. An assumption was made to estimate the losses in the vaneless diffuser to evaluate the effect of the instability development on its performance. The result has shown that the arising of rotating stall has a positive effect on the diffuser performance. Two possible reasons are proposed: (1) a blockage in the diffuser due to the unstable cells which shortens the streamlines and decreased the friction losses along the vaneless diffuser; (2) the topology of rotating stall cells results in the convection of fluid coming from outside part of the pump model to the vaneless diffuser.Show less >
Show more >Rotating stall in a vaneless diffuser of radial flow pump is studied. The measurements consist of: (i) unsteady pressure measurements delivered by two microphones; and (ii) nine steady pressure taps mounted in one radial line to measure the pressure recovery in the vaneless diffuser. Spectrum analysis was used to identify and characterize rotating stall. An assumption was made to estimate the losses in the vaneless diffuser to evaluate the effect of the instability development on its performance. The result has shown that the arising of rotating stall has a positive effect on the diffuser performance. Two possible reasons are proposed: (1) a blockage in the diffuser due to the unstable cells which shortens the streamlines and decreased the friction losses along the vaneless diffuser; (2) the topology of rotating stall cells results in the convection of fluid coming from outside part of the pump model to the vaneless diffuser.Show less >
Language :
Anglais
Popular science :
Non
Source :
Files
- https://hal.archives-ouvertes.fr/hal-02140401/document
- Open access
- Access the document