Control of a DC-AC inverter in a wind ...
  • BibTeX
  • CSV
  • Excel
  • RIS

Document type :
Autre communication scientifique (congrès sans actes - poster - séminaire...): Communication dans un congrès avec actes
DOI :
10.1109/SYSTOL.2016.7739824
Title :
Control of a DC-AC inverter in a wind energy generation system using T-S fuzzy modeling
Author(s) :
Harrabi, Naziha [Auteur]
Souissi, Mansour [Auteur]
Aitouche, Abdel [Auteur]
Centre de Recherche en Informatique, Signal et Automatique de Lille - UMR 9189 [CRIStAL]
Chaabane, Mohamed [Auteur]
Conference title :
Control and Fault-Tolerant Systems (SysTol), 2016 3rd Conference on
Conference organizers(s) :
Polytechnique Barcelone
City :
Barcelone
Country :
Espagne
Start date of the conference :
2016-09-07
English keyword(s) :
Inverters
Mathematical model
Wind energy
Voltage control
Wind power generation
Wind turbines
Generators
HAL domain(s) :
Sciences de l'ingénieur [physics]/Automatique / Robotique
English abstract : [en]
The wind generation system treated in this paper is composed of a fixed pitch angle wind turbine followed by a Permanent Magnet Synchronous Generator (PMSG) and power electronic converters AC-DC-AC which are coupled to a ...
Show more >
The wind generation system treated in this paper is composed of a fixed pitch angle wind turbine followed by a Permanent Magnet Synchronous Generator (PMSG) and power electronic converters AC-DC-AC which are coupled to a DC link. This work deals with the control of the inverter in order to ensure a constant DC link voltage. The control design is based on Takagi Sugeno fuzzy model. Stability analysis of the problem is realized using Lyapunov theorem and H-infinity performance. In order to calculate the controller gains, the problem is treated by means of Linear Matrix Inequality (LMI). Simulation results are carried out using MATLAB/SIMULINK to test the effectiveness of the proposed control algorithm.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Collections :
  • Centre de Recherche en Informatique, Signal et Automatique de Lille (CRIStAL) - UMR 9189
Source :
Harvested from HAL
Université de Lille

Mentions légales
Accessibilité : non conforme
Université de Lille © 2017