Optimization method of CM inductor volume ...
Document type :
Article dans une revue scientifique: Article original
Permalink :
Title :
Optimization method of CM inductor volume taking into account the magnetic core saturation issues
Author(s) :
Zaidi, Bilel [Auteur]
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Videt, Arnaud [Auteur]
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
IDIR, Nadir [Auteur]
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Videt, Arnaud [Auteur]

Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
IDIR, Nadir [Auteur]

Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Journal title :
IEEE Transactions on Power Electronics
Volume number :
34
Pages :
4279-4291
Publisher :
Institute of Electrical and Electronics Engineers (IEEE)
Publication date :
2019-05
ISSN :
0885-8993
English keyword(s) :
Electromagnetic compatibility (EMC) standard
inductor volume design
magnetic core saturation
optimization
inductor volume design
magnetic core saturation
optimization
HAL domain(s) :
Sciences de l'ingénieur [physics]
English abstract : [en]
Electromagnetic interference filters are broadly used in power electronic systems in order to respect electromagnetic compatibility normative constraints, which considerably increase overall cost and volume mainly because ...
Show more >Electromagnetic interference filters are broadly used in power electronic systems in order to respect electromagnetic compatibility normative constraints, which considerably increase overall cost and volume mainly because of the common-mode (CM) inductor. In this paper, a new method to calculate the optimal volume of the CM inductor is proposed. It takes into account core saturation issues that may greatly impact inductor volume and filter performances. Consequently, it is shown that in some cases, increasing the inductance value up to the best value can significantly reduce the filter volume in addition to further enhancing the filter attenuation. It is also shown that different nearly-best inductor geometrical parameters with different shape factors can be obtained, which provides an important degree of freedom to designers while introducing the filter in the energy conversion system.Show less >
Show more >Electromagnetic interference filters are broadly used in power electronic systems in order to respect electromagnetic compatibility normative constraints, which considerably increase overall cost and volume mainly because of the common-mode (CM) inductor. In this paper, a new method to calculate the optimal volume of the CM inductor is proposed. It takes into account core saturation issues that may greatly impact inductor volume and filter performances. Consequently, it is shown that in some cases, increasing the inductance value up to the best value can significantly reduce the filter volume in addition to further enhancing the filter attenuation. It is also shown that different nearly-best inductor geometrical parameters with different shape factors can be obtained, which provides an important degree of freedom to designers while introducing the filter in the energy conversion system.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Research team(s) :
Équipe Électronique de puissance
Submission date :
2020-09-14T08:17:00Z
2022-10-25T14:29:13Z
2023-09-08T11:51:01Z
2022-10-25T14:29:13Z
2023-09-08T11:51:01Z
Files
- Author_version_postprint.pdf
- Version finale acceptée pour publication (postprint)
- Open access
- Access the document