Overview of tools for the measurement of ...
Type de document :
Article dans une revue scientifique: Article de synthèse/Review paper
PMID :
URL permanente :
Titre :
Overview of tools for the measurement of the orbital volume and their applications to orbital surgery
Auteur(s) :
Sentucq, Camille [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Schlund, Matthias [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Bouet, Benjamin [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Garms, Martin [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Ferri, Joel [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Jacques, Thibaut [Auteur]
Radiologie et Imagerie Musculo-Squelettique [CHU Lille]
Nicot, Romain [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Schlund, Matthias [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Bouet, Benjamin [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Garms, Martin [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Ferri, Joel [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Jacques, Thibaut [Auteur]
Radiologie et Imagerie Musculo-Squelettique [CHU Lille]
Nicot, Romain [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Titre de la revue :
Journal of plastic, reconstructive & aesthetic surgery
Nom court de la revue :
J Plast Reconstr Aesthet Surg
Numéro :
74
Pagination :
581-591
Date de publication :
2020-09-20
ISSN :
1878-0539
Mot(s)-clé(s) en anglais :
Orbital volume measurement
Orbital surgery
Pre-operative planning
Enophthalmos
Orbital reconstruction
Orbital surgery
Pre-operative planning
Enophthalmos
Orbital reconstruction
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
There are numerous applications in craniofacial surgery with orbital volume (OV) modification. The careful management of the OV is fundamental to obtain good esthetic and functional results in orbital surgery. With the ...
Lire la suite >There are numerous applications in craniofacial surgery with orbital volume (OV) modification. The careful management of the OV is fundamental to obtain good esthetic and functional results in orbital surgery. With the growth of computer-aided design - computer-aided manufacturing (CAD-CAM) technologies, patient-specific implants and custom-made reconstruction are being used increasingly. The precise measurement of the OV before surgery is becoming a necessity for craniofacial surgeons. There is no consensus on orbital volume measurements (OVMs). Manual segmentation of computed tomography (CT) images is the most used method to determine the OV, but it is time-consuming and very sensitive to operator errors. Here, we describe the various methods of orbital volumetry validated in the literature that can be used by surgeons in preoperative planning of orbital surgery. We also describe the leading software employed for these methods and discuss clinical use (posttraumatic enophthalmos prediction and orbital reconstruction) in which OVMs are important.Lire moins >
Lire la suite >There are numerous applications in craniofacial surgery with orbital volume (OV) modification. The careful management of the OV is fundamental to obtain good esthetic and functional results in orbital surgery. With the growth of computer-aided design - computer-aided manufacturing (CAD-CAM) technologies, patient-specific implants and custom-made reconstruction are being used increasingly. The precise measurement of the OV before surgery is becoming a necessity for craniofacial surgeons. There is no consensus on orbital volume measurements (OVMs). Manual segmentation of computed tomography (CT) images is the most used method to determine the OV, but it is time-consuming and very sensitive to operator errors. Here, we describe the various methods of orbital volumetry validated in the literature that can be used by surgeons in preoperative planning of orbital surgery. We also describe the leading software employed for these methods and discuss clinical use (posttraumatic enophthalmos prediction and orbital reconstruction) in which OVMs are important.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
Inserm
Université de Lille
Inserm
Université de Lille
Collections :
Date de dépôt :
2021-01-20T15:58:56Z
2024-02-19T10:27:15Z
2024-02-19T10:27:15Z