One year outcomes of 101 begraft stent ...
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
One year outcomes of 101 begraft stent grafts used as bridging stents in fenestrated endovascular repairs
Author(s) :
Spear, Rafaelle [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Sobocinski, Jonathan [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Delloye, Matthieu [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Azzaoui, Richard [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Fabre, Dominique [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Haulon, Stephan [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Sobocinski, Jonathan [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Delloye, Matthieu [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Azzaoui, Richard [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Fabre, Dominique [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Haulon, Stephan [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Journal title :
European Journal of Vascular and Endovascular Surgery
Abbreviated title :
Eur J Vasc Endovasc Surg
Volume number :
55
Pages :
504-510
Publication date :
2018-02-28
ISSN :
1532-2165
English keyword(s) :
Abdominal
Stents
Endovascular procedures
Aortic aneurysms
Stents
Endovascular procedures
Aortic aneurysms
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair ...
Show more >To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is required to confirm these promising results.Show less >
Show more >To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is required to confirm these promising results.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
CHU Lille
Inserm
Université de Lille
Inserm
Université de Lille
Collections :
Submission date :
2021-01-20T15:59:06Z
2024-02-19T15:09:38Z
2024-02-19T15:09:38Z