Fast epi-detected broadband multiplex CARS ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
URL permanente :
Titre :
Fast epi-detected broadband multiplex CARS and SHG imaging of mouse skull cells
Auteur(s) :
Capitaine, Erwan [Auteur]
XLIM [XLIM]
Moussa, Nawel Ould [Auteur]
XLIM [XLIM]
Louot, Christophe [Auteur]
XLIM [XLIM]
Bardet, Sylvia M. [Auteur]
XLIM [XLIM]
Kano, Hideaki [Auteur]
Université de Tsukuba = University of Tsukuba
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Lévêque, Philippe [Auteur]
XLIM [XLIM]
Couderc, Vincent [Auteur]
XLIM [XLIM]
Leproux, Philippe [Auteur]
XLIM [XLIM]
XLIM [XLIM]
Moussa, Nawel Ould [Auteur]
XLIM [XLIM]
Louot, Christophe [Auteur]
XLIM [XLIM]
Bardet, Sylvia M. [Auteur]
XLIM [XLIM]
Kano, Hideaki [Auteur]
Université de Tsukuba = University of Tsukuba
Duponchel, Ludovic [Auteur]
Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement (LASIRE) - UMR 8516
Lévêque, Philippe [Auteur]
XLIM [XLIM]
Couderc, Vincent [Auteur]
XLIM [XLIM]
Leproux, Philippe [Auteur]
XLIM [XLIM]
Titre de la revue :
Biomedical optics express
Numéro :
9
Pagination :
245-245
Date de publication :
2018-01
Discipline(s) HAL :
Chimie/Chimie théorique et/ou physique
Résumé en anglais : [en]
We present a bimodal imaging system able to obtain epi-detected mutiplex coherent
anti-Stokes Raman scattering (M-CARS) and second harmonic generation (SHG) signals coming
from biological samples. We studied a fragment ...
Lire la suite >We present a bimodal imaging system able to obtain epi-detected mutiplex coherent anti-Stokes Raman scattering (M-CARS) and second harmonic generation (SHG) signals coming from biological samples. We studied a fragment of mouse parietal bone and could detect broadband anti-Stokes and SHG responses originating from bone cells and collagen respectively. In addition we compared two post-processing methods to retrieve the imaginary part of the third-order nonlinear susceptibility related to the spontaneous Raman scattering.Lire moins >
Lire la suite >We present a bimodal imaging system able to obtain epi-detected mutiplex coherent anti-Stokes Raman scattering (M-CARS) and second harmonic generation (SHG) signals coming from biological samples. We studied a fragment of mouse parietal bone and could detect broadband anti-Stokes and SHG responses originating from bone cells and collagen respectively. In addition we compared two post-processing methods to retrieve the imaginary part of the third-order nonlinear susceptibility related to the spontaneous Raman scattering.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CNRS
ENSCL
Université de Lille
ENSCL
Université de Lille
Collections :
Équipe(s) de recherche :
Propriétés magnéto structurales des matériaux (PMSM)
Date de dépôt :
2021-11-16T08:23:34Z
2024-02-23T10:40:53Z
2024-02-23T10:40:53Z
Fichiers
- boe-9-1-245.pdf
- Version éditeur
- Accès libre
- Accéder au document