Assessing the applicability of the new global lung function initiative reference values for the diffusing capacity of the lung for carbon monoxide in a large population set
Auteur(s) :
Wardyn, Pierre-Marie [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
De Broucker, Virginie [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Service d'explorations fonctionnelles respiratoires [Lille]
Chenivesse, Cecile [Auteur]
Centre d'Infection et d'Immunité de Lille (CIIL) - U1019 - UMR 9017
Sobaszek, Annie [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Van Bulck, Richard [Auteur]
Service d'explorations fonctionnelles respiratoires [Lille]
Perez, Thierry [Auteur]
Centre d'Infection et d'Immunité de Lille (CIIL) - U1019 - UMR 9017
Edme, Jean-Louis [Auteur]
IMPact de l’Environnement Chimique sur la Santé humaine (IMPECS) - EA 4483
Hulo, Sebastien [Auteur]
IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483

IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
De Broucker, Virginie [Auteur]
Impact de l'environnement chimique sur la santé humaine - ULR 4483 [IMPECS]
Service d'explorations fonctionnelles respiratoires [Lille]
Chenivesse, Cecile [Auteur]

Centre d'Infection et d'Immunité de Lille (CIIL) - U1019 - UMR 9017
Sobaszek, Annie [Auteur]

IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Van Bulck, Richard [Auteur]
Service d'explorations fonctionnelles respiratoires [Lille]
Perez, Thierry [Auteur]

Centre d'Infection et d'Immunité de Lille (CIIL) - U1019 - UMR 9017
Edme, Jean-Louis [Auteur]

IMPact de l’Environnement Chimique sur la Santé humaine (IMPECS) - EA 4483
Hulo, Sebastien [Auteur]

IMPact de l'Environnement Chimique sur la Santé humaine (IMPECS) - ULR 4483
Titre de la revue :
PLoS One
Nom court de la revue :
PLoS One
Numéro :
16
Pagination :
e0245434
Date de publication :
2021-01-01
ISSN :
1932-6203
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
The single-breath diffusing capacity of the lung for carbon monoxide (DLCO) interpretation needs the comparison of measured values to reference values. In 2017, the Global Lung Function Initiative published new reference ...
Lire la suite >The single-breath diffusing capacity of the lung for carbon monoxide (DLCO) interpretation needs the comparison of measured values to reference values. In 2017, the Global Lung Function Initiative published new reference values (GLI-2017) for DLCO, alveolar volume (VA) and transfer coefficient of the lung for carbon monoxide (KCO). We aimed to assess the applicability of GLI-2017 reference values for DLCO on a large population by comparing them to the European Community of Steel and Coal equations of 1993 (ECSC-93) widely used. In this retrospective study, spirometric indices, total lung capacity, DLCO, VA and KCO were measured in adults classified in 5 groups (controls, asthma, chronic bronchitis, cystic fibrosis, and interstitial lung diseases (ILD)). Statistical analysis comparing the 2 equations sets were stratified by sex. 4180 tests were included. GLI-2017 z-scores of the 3 DLCO indices of the controls (n = 150) are nearer to 0 (expected value in a normal population) than ECSC-93 z-scores. All groups combined, in both genders, DLCO GLI-2017 z-scores and %predicted are significantly higher than ECSC z-scores and %predicted. In the ILD group, differences between the 2 equation sets depend on the DLCO impairment severity: GLI-2017 z-scores are higher than ECSC z-scores in patients with no or "mild" decrease in DLCO, but are lower in "moderate" or "severe" decrease. GLI-2017 reference values for DLCO are more suitable to our population and influence the diagnostic criteria and severity definition of several lung diseases.Lire moins >
Lire la suite >The single-breath diffusing capacity of the lung for carbon monoxide (DLCO) interpretation needs the comparison of measured values to reference values. In 2017, the Global Lung Function Initiative published new reference values (GLI-2017) for DLCO, alveolar volume (VA) and transfer coefficient of the lung for carbon monoxide (KCO). We aimed to assess the applicability of GLI-2017 reference values for DLCO on a large population by comparing them to the European Community of Steel and Coal equations of 1993 (ECSC-93) widely used. In this retrospective study, spirometric indices, total lung capacity, DLCO, VA and KCO were measured in adults classified in 5 groups (controls, asthma, chronic bronchitis, cystic fibrosis, and interstitial lung diseases (ILD)). Statistical analysis comparing the 2 equations sets were stratified by sex. 4180 tests were included. GLI-2017 z-scores of the 3 DLCO indices of the controls (n = 150) are nearer to 0 (expected value in a normal population) than ECSC-93 z-scores. All groups combined, in both genders, DLCO GLI-2017 z-scores and %predicted are significantly higher than ECSC z-scores and %predicted. In the ILD group, differences between the 2 equation sets depend on the DLCO impairment severity: GLI-2017 z-scores are higher than ECSC z-scores in patients with no or "mild" decrease in DLCO, but are lower in "moderate" or "severe" decrease. GLI-2017 reference values for DLCO are more suitable to our population and influence the diagnostic criteria and severity definition of several lung diseases.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
CNRS
Inserm
Institut Pasteur de Lille
Université de Lille
CNRS
Inserm
Institut Pasteur de Lille
Université de Lille
Collections :
Date de dépôt :
2022-02-02T10:23:28Z
2022-08-24T09:36:01Z
2022-08-24T09:36:01Z
Fichiers
- Wardyn et al..pdf
- Version éditeur
- Accès libre
- Accéder au document