Immunoassay quantification of human insulin added to ternary parenteral nutrition containers: comparison of two methods
Auteur(s) :
Henry, Heloise [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Simon, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Seguy, David [Auteur]
Lille Inflammation Research International Center - U 995 [LIRIC]
D'herbomez, Michele [Auteur]
Barthelemy, Christine [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Décaudin, Bertrand [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Dine, thierry [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Odou, Pascal [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Simon, Nicolas [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Seguy, David [Auteur]

Lille Inflammation Research International Center - U 995 [LIRIC]
D'herbomez, Michele [Auteur]
Barthelemy, Christine [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Décaudin, Bertrand [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Dine, thierry [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Odou, Pascal [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Titre de la revue :
Analytical and bioanalytical chemistry
Nom court de la revue :
Anal. Bioanal. Chem.
Numéro :
409
Pagination :
3677-3684
Date de publication :
2017-05-01
ISSN :
1618-2642
Mot(s)-clé(s) :
Mesh:Electrochemical Techniques/methods
Mesh:Hyperglycemia/blood
Mesh:Limit of Detection
Mesh:Radioimmunoassay/methods
Mesh:Recombinant Proteins/administration & dosage
Mesh:Parenteral Nutrition*/methods
Mesh:Recombinant Proteins/blood
Mesh:Insulin/blood*
Mesh:Immunoassay/methods*
Mesh:Insulin/administration & dosage
Mesh:Hypoglycemic Agents/administration & dosage
Mesh:Hypoglycemic Agents/blood*
Mesh:Hyperglycemia/therapy
Mesh:Humans
Parenteral nutrition solutions
Accuracy profile
Validation
Immunoassay
Human insulin
Mesh:Hyperglycemia/blood
Mesh:Limit of Detection
Mesh:Radioimmunoassay/methods
Mesh:Recombinant Proteins/administration & dosage
Mesh:Parenteral Nutrition*/methods
Mesh:Recombinant Proteins/blood
Mesh:Insulin/blood*
Mesh:Immunoassay/methods*
Mesh:Insulin/administration & dosage
Mesh:Hypoglycemic Agents/administration & dosage
Mesh:Hypoglycemic Agents/blood*
Mesh:Hyperglycemia/therapy
Mesh:Humans
Parenteral nutrition solutions
Accuracy profile
Validation
Immunoassay
Human insulin
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Adding insulin directly into infusion bags seems to be a useful method for controlling hyperglycemia in patients under ternary parenteral nutrition (TPN). Its efficacy is assessed by glycemic monitoring but few data are ...
Lire la suite >Adding insulin directly into infusion bags seems to be a useful method for controlling hyperglycemia in patients under ternary parenteral nutrition (TPN). Its efficacy is assessed by glycemic monitoring but few data are available on insulin stability in this situation. Among the various methods for quantifying insulin levels in human serum, the immunoassay ones seemed potentially appropriate for a TPN admixture containing high lipid concentrations. We sought to identify and validate which of two immunoassay methods was the better to quantify human insulin and consequently be adapted to studying its stability in a TPN admixture. Two immunoassay methods to quantify recombinant human insulin were assessed in industrial TPN: an immunoradiometric assay (IRMA) and an immunoelectrochemiluminometric assay (IECMA). Validation trials for both methods were based on the accuracy profile method. Interference with immunometric assays due to the high lipidic content of TPN was eliminated through an improved preparation protocol using a bovine serum albumin (BSA) diluted in phosphate buffer saline (PBS). The relative total error of IECMA varied from 1.74 to 4.52% while it varied from -0.32 to 8.37% with IRMA. Only IECMA provided an accuracy profile with a 95% confidence interval of calculated-tolerance limits falling between the chosen acceptance limits (i.e., total error ≤±10%). IECMA combined with a BSA dilution is a simple and semi-automatic method that provides an accurate quantification of human insulin in a TPN admixture without any interference from lipids.Lire moins >
Lire la suite >Adding insulin directly into infusion bags seems to be a useful method for controlling hyperglycemia in patients under ternary parenteral nutrition (TPN). Its efficacy is assessed by glycemic monitoring but few data are available on insulin stability in this situation. Among the various methods for quantifying insulin levels in human serum, the immunoassay ones seemed potentially appropriate for a TPN admixture containing high lipid concentrations. We sought to identify and validate which of two immunoassay methods was the better to quantify human insulin and consequently be adapted to studying its stability in a TPN admixture. Two immunoassay methods to quantify recombinant human insulin were assessed in industrial TPN: an immunoradiometric assay (IRMA) and an immunoelectrochemiluminometric assay (IECMA). Validation trials for both methods were based on the accuracy profile method. Interference with immunometric assays due to the high lipidic content of TPN was eliminated through an improved preparation protocol using a bovine serum albumin (BSA) diluted in phosphate buffer saline (PBS). The relative total error of IECMA varied from 1.74 to 4.52% while it varied from -0.32 to 8.37% with IRMA. Only IECMA provided an accuracy profile with a 95% confidence interval of calculated-tolerance limits falling between the chosen acceptance limits (i.e., total error ≤±10%). IECMA combined with a BSA dilution is a simple and semi-automatic method that provides an accurate quantification of human insulin in a TPN admixture without any interference from lipids.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
CHU Lille
Inserm
CHU Lille
Inserm
Collections :
Équipe(s) de recherche :
Innovation/évaluation des médicaments injectables
Modélisation biopharmaceutique et pharmacocinétique
Innovation/évaluation des dispositifs médicaux de perfusion
Nutritional modulation of inflammation and infection
Modélisation biopharmaceutique et pharmacocinétique
Innovation/évaluation des dispositifs médicaux de perfusion
Nutritional modulation of inflammation and infection
Date de dépôt :
2019-02-26T17:07:11Z
2019-05-03T08:28:52Z
2019-06-06T11:35:36Z
2019-05-03T08:28:52Z
2019-06-06T11:35:36Z
Fichiers
- manuscript submitted post print.pdf
- Version finale acceptée pour publication
- Accès libre
- Accéder au document
- Henry2017_Article_ImmunoassayQuantificationOfHum definitive.pdf
- Version éditeur
- Accès confidentiel
- Accéder au document