Transparent fire protective sol-gel coating ...
Document type :
Article dans une revue scientifique: Article original
Permalink :
Title :
Transparent fire protective sol-gel coating for wood panels
Author(s) :
Bellayer, Séverine [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Gossiaux, Alexandre [Auteur]
Duquesne, Sophie [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Dewailly, Benjamin [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Bachelet, Pierre [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Jimenez, Maude [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Gossiaux, Alexandre [Auteur]

Unité Matériaux et Transformations (UMET) - UMR 8207
Gossiaux, Alexandre [Auteur]
Duquesne, Sophie [Auteur]

Unité Matériaux et Transformations (UMET) - UMR 8207
Dewailly, Benjamin [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Bachelet, Pierre [Auteur]

Unité Matériaux et Transformations (UMET) - UMR 8207
Jimenez, Maude [Auteur]

Unité Matériaux et Transformations (UMET) - UMR 8207
Gossiaux, Alexandre [Auteur]
Journal title :
Polymer testing
Volume number :
110
Pages :
107579
Publication date :
2022-06
ISSN :
0142-9418
HAL domain(s) :
Chimie/Matériaux
English abstract : [en]
A transparent fire protective sol-gel coating deposited on wood has been evaluated using different fire tests, such as mass loss cone, mini single burning item and furnace tests. The heat release rate and total heat release ...
Show more >A transparent fire protective sol-gel coating deposited on wood has been evaluated using different fire tests, such as mass loss cone, mini single burning item and furnace tests. The heat release rate and total heat release during combustion, but also the flame spread behavior and the thermal protection performances of the coatings have been studied. Two processes to apply the sol-gel coating on wood have been assessed to show the thickness dependence of the fire performance. When deposited as a thick coating (800 μm thick) on wood, the sol-gel coating lowers the total heat release, decreases the flame spread and greatly improves the thermal protection of the substrate.Show less >
Show more >A transparent fire protective sol-gel coating deposited on wood has been evaluated using different fire tests, such as mass loss cone, mini single burning item and furnace tests. The heat release rate and total heat release during combustion, but also the flame spread behavior and the thermal protection performances of the coatings have been studied. Two processes to apply the sol-gel coating on wood have been assessed to show the thickness dependence of the fire performance. When deposited as a thick coating (800 μm thick) on wood, the sol-gel coating lowers the total heat release, decreases the flame spread and greatly improves the thermal protection of the substrate.Show less >
Language :
Anglais
Peer reviewed article :
Oui
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
CNRS
INRAE
ENSCL
CNRS
INRAE
ENSCL
Collections :
Research team(s) :
Procédés de Recyclage et de Fonctionnalisation (PReF)
Submission date :
2022-12-07T13:03:12Z
2022-12-09T06:57:57Z
2022-12-09T06:57:57Z
Files
- 1-s2.0-S0142941822001040-main.pdf
- Version éditeur
- Open access
- Access the document
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States