How bulk fluid renewal can affect in vitro drug release from PLGA implants: Importance of the experimental set-up
Auteur(s) :
Bassand, Celine [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Benabed, L. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Freitag, J. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Verin, Jérémy [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Florence [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Juergen [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Advanced Drug Delivery Systems (ADDS) - U1008
Benabed, L. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Freitag, J. [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Verin, Jérémy [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Florence [Auteur]

Advanced Drug Delivery Systems (ADDS) - U1008
Siepmann, Juergen [Auteur]

Advanced Drug Delivery Systems (ADDS) - U1008
Titre de la revue :
International Journal of Pharmaceutics: X
Nom court de la revue :
Int J Pharm X
Numéro :
4
Pagination :
100131
Date de publication :
2022-10-08
ISSN :
2590-1567
Mot(s)-clé(s) :
PLGA
Implant
Controlled drug delivery
Experimental set-up
Ibuprofen
Implant
Controlled drug delivery
Experimental set-up
Ibuprofen
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
The aim of this study was to better understand the potential impact of partial vs. complete renewal of the bulk fluid during drug release measurements from poly (lactic-co-glycolic acid) (PLGA)-based implants. A “standard ...
Lire la suite >The aim of this study was to better understand the potential impact of partial vs. complete renewal of the bulk fluid during drug release measurements from poly (lactic-co-glycolic acid) (PLGA)-based implants. A “standard experimental set-up”, in which the implants were directly exposed to well agitated phosphate buffer pH 7.4 was used, as well as set-ups, in which the implants were embedded within agarose hydrogels (mimicking living tissue). The gels were exposed to well agitated phosphate buffer pH 7.4. Ibuprofen-loaded implants were prepared by hot melt extrusion. The systems were thoroughly characterized before and during drug release by optical and scanning electron microscopy, gravimetric analysis, pH and solubility measurements as well as gel permeation chromatography. The bulk fluid was either completely or partially replaced by fresh medium at each sampling time point. In all cases, sink conditions were provided in the agitated bulk fluids throughout the experiments. Interestingly, the agarose set-ups did not show any noteworthy impact of the bulk fluid sampling volume on the observed drug release patterns, whereas complete fluid renewal in the “standard set-up” led to accelerated drug release. This could be explained by the considerable fragility of the implants once substantial polymer swelling set on, transforming them into PLGA gels: Complete fluid renewal caused partial disintegration and damage of the highly swollen systems, decreasing the lengths of the diffusion pathways for the drug. The mechanical stress is very much reduced at low sampling volumes, or if the implants are embedded within agarose gels. Thus, great care must be taken when defining the conditions for in vitro drug release measurements from PLGA-based implants: Once substantial system swelling sets on, the devices become highly fragile.Lire moins >
Lire la suite >The aim of this study was to better understand the potential impact of partial vs. complete renewal of the bulk fluid during drug release measurements from poly (lactic-co-glycolic acid) (PLGA)-based implants. A “standard experimental set-up”, in which the implants were directly exposed to well agitated phosphate buffer pH 7.4 was used, as well as set-ups, in which the implants were embedded within agarose hydrogels (mimicking living tissue). The gels were exposed to well agitated phosphate buffer pH 7.4. Ibuprofen-loaded implants were prepared by hot melt extrusion. The systems were thoroughly characterized before and during drug release by optical and scanning electron microscopy, gravimetric analysis, pH and solubility measurements as well as gel permeation chromatography. The bulk fluid was either completely or partially replaced by fresh medium at each sampling time point. In all cases, sink conditions were provided in the agitated bulk fluids throughout the experiments. Interestingly, the agarose set-ups did not show any noteworthy impact of the bulk fluid sampling volume on the observed drug release patterns, whereas complete fluid renewal in the “standard set-up” led to accelerated drug release. This could be explained by the considerable fragility of the implants once substantial polymer swelling set on, transforming them into PLGA gels: Complete fluid renewal caused partial disintegration and damage of the highly swollen systems, decreasing the lengths of the diffusion pathways for the drug. The mechanical stress is very much reduced at low sampling volumes, or if the implants are embedded within agarose gels. Thus, great care must be taken when defining the conditions for in vitro drug release measurements from PLGA-based implants: Once substantial system swelling sets on, the devices become highly fragile.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
Inserm
CHU Lille
Inserm
CHU Lille
Collections :
Date de dépôt :
2022-12-08T01:10:38Z
2023-03-01T15:19:10Z
2023-03-01T15:19:10Z
Fichiers
- 1-s2.0-S2590156722000202-main.pdf
- Version éditeur
- Accès libre
- Accéder au document