One Year Assessment of the Hearing ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
PMID :
URL permanente :
Titre :
One Year Assessment of the Hearing Preservation Potential of the EVO Electrode Array.
Auteur(s) :
Guevara, Nicolas [Auteur]
Institut Universitaire de la Face et du Cou [Nice]
Parietti-Winkler, Cécile [Auteur]
Centre Hospitalier Régional Universitaire de Nancy [CHRU Nancy]
Godey, Benoît [Auteur]
Centre Hospitalier Universitaire de Rennes [CHU Rennes] = Rennes University Hospital [Pontchaillou]
Franco-Vidal, Valérie [Auteur]
CHU de Bordeaux Pellegrin [Bordeaux]
Gnansia, Dan [Auteur]
Oticon Medical / Neurelec
Ardoint, Marine [Auteur]
Oticon Medical / Neurelec
Hoen, Michel [Auteur]
Oticon Medical / Neurelec
Karoui, Chadlia [Auteur]
Oticon Medical / Neurelec
Truy, Eric [Auteur]
Département d'ORL, chirurgie cervico-maxillo-faciale et d'audiophonologie [Hôpital Edouard Herriot - HCL]
Vincent, Christophe [Auteur]
Advanced Drug Delivery Systems (ADDS) - U1008
Mosnier, Isabelle [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Nguyen, Yann [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Institut Universitaire de la Face et du Cou [Nice]
Parietti-Winkler, Cécile [Auteur]
Centre Hospitalier Régional Universitaire de Nancy [CHRU Nancy]
Godey, Benoît [Auteur]
Centre Hospitalier Universitaire de Rennes [CHU Rennes] = Rennes University Hospital [Pontchaillou]
Franco-Vidal, Valérie [Auteur]
CHU de Bordeaux Pellegrin [Bordeaux]
Gnansia, Dan [Auteur]
Oticon Medical / Neurelec
Ardoint, Marine [Auteur]
Oticon Medical / Neurelec
Hoen, Michel [Auteur]
Oticon Medical / Neurelec
Karoui, Chadlia [Auteur]
Oticon Medical / Neurelec
Truy, Eric [Auteur]
Département d'ORL, chirurgie cervico-maxillo-faciale et d'audiophonologie [Hôpital Edouard Herriot - HCL]
Vincent, Christophe [Auteur]

Advanced Drug Delivery Systems (ADDS) - U1008
Mosnier, Isabelle [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Nguyen, Yann [Auteur]
CHU Pitié-Salpêtrière [AP-HP]
Titre de la revue :
Journal of Clinical Medicine
Nom court de la revue :
J Clin Med
Numéro :
10
Pagination :
5604
Éditeur :
MDPI
Date de publication :
2021-12-14
ISSN :
2077-0383
Mot(s)-clé(s) :
cochlear implantation
hearing preservation
HEARRING classification
functional hearing
EVO electrode array
hearing preservation
HEARRING classification
functional hearing
EVO electrode array
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Sciences du Vivant [q-bio]
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of ...
Lire la suite >Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125–500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed.Lire moins >
Lire la suite >Background: A prospective longitudinal multicentre study was conducted to assess the one-year postsurgical hearing preservation profile of the EVOTM electrode array. Methods: Fifteen adults presenting indications of electro-acoustic stimulation (pure-tone audiometry (PTA) thresholds ≤70 dB below 750 Hz) were implanted with the EVO™ electrode array. Hearing thresholds were collected at five time-points from CI activation to twelve months (12M) after activation. Hearing thresholds and hearing preservation profiles (HEARRING group classification) were assessed. Results: All subjects had measurable hearing thresholds at follow-up. No case of complete loss of hearing or minimal hearing preservation was reported at any time point. At activation (Nact = 15), five participants had complete hearing preservation, and ten participants had partial hearing preservation. At the 12M time point (N12m = 6), three participants had complete hearing preservation, and three participants had partial hearing preservation. Mean hearing loss at activation was 11 dB for full range PTA and 25 dB for PTAs low-frequency (125–500 Hz). Conclusions: This study provides the first longitudinal follow-up on associated hearing profiles to the EVO™ electrode array, which are comparable to the literature. However, other studies on larger populations should be performed.Lire moins >
Audience :
Internationale
Établissement(s) :
Université de Lille
Inserm
CHU Lille
Inserm
CHU Lille
Collections :
Date de dépôt :
2022-12-08T01:19:57Z
2023-03-01T09:55:09Z
2023-03-01T09:55:09Z
Fichiers
- jcm-10-05604.pdf
- Non spécifié
- Accès libre
- Accéder au document