Efficiency of four solutions in removing ...
Type de document :
Article dans une revue scientifique: Article original
PMID :
URL permanente :
Titre :
Efficiency of four solutions in removing 23 conventional antineoplastic drugs from contaminated surfaces.
Auteur(s) :
Simon, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Guichard, Nicolas [Auteur]
Odou, Pascal [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Décaudin, Bertrand [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Bonnabry, Pascal [Auteur]
Fleury-Souverain, Sandrine [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Guichard, Nicolas [Auteur]
Odou, Pascal [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Décaudin, Bertrand [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées (GRITA) - ULR 7365
Bonnabry, Pascal [Auteur]
Fleury-Souverain, Sandrine [Auteur]
Titre de la revue :
PLoS One
Nom court de la revue :
PLOS ONE
Numéro :
15
Pagination :
e0235131
Date de publication :
2020-06-22
ISSN :
1932-6203
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Background
Residual contamination by intravenous conventional antineoplastic drugs (ICAD) is still a daily issue in hospital facilities. This study aimed to compare the efficiency (EffQ) of 4 different solutions to remove ...
Lire la suite >Background Residual contamination by intravenous conventional antineoplastic drugs (ICAD) is still a daily issue in hospital facilities. This study aimed to compare the efficiency (EffQ) of 4 different solutions to remove 23 widely used ICADs from surfaces. Method and findings A solution containing 23 ICADs (4 alkylating agents, 8 antimetabolites, 2 topo-I inhibitors, 6 topo-II inhibitors and 3 spindle poisons) was spread over 100 cm2 stainless steel. After drying, decontamination was carried out using 10×10 cm wipes moistened with 300 μL of one of the following solutions: 70% isopropanol (S1); ethanol-hydrogen peroxide 91.6–50.0 mg/g (S2); 10−2 M sodium dodecyl sulphate/isopropanol 80/20 (S3) or 0.5% sodium hypochlorite (S4). Six tests were performed for each decontamination solution. Two modalities were tested: a single wipe motion from top to bottom or vigorous wiping (n = 6 for each modality). Residual contamination was measured with a validated liquid chromatography with tandem mass spectrometry detection method. Solution efficiency (in %) was computed as follows: EffQ = 1–(quantity after decontamination/quantity before decontamination), as median (min–max) for the 23 ICADs. The overall decontamination efficiency (EffQ) of the 4 solutions was compared by a Kruskall-Wallis test. Decontamination modalities were compared for each solution and per ICAD with a Mann-Whitney test (p<0.05). EffQ were significantly different from one solution to the next for single wipe motion decontamination: 79.9% (69.3–100), 86.5% (13.0–100), 85.4% (56.5–100) and 100% (52.9–100) for S1, S2, S3 and S4 (p<0.0001), respectively. Differences were also significant for vigorous decontamination: EffQ of 84.3% (66.0–100), 92.3% (68.7–100), 99.6% (84.8–100) and 100% (82.9–100) for S1, S2, S3 and S4, respectively (p<0.0001). Generally, vigorous decontamination increased EffQ for all tested solutions and more significantly for the surfactant. Conclusion Decontamination efficiency depended on the solution used but also on the application modality. An SDS admixture seems to be a good alternative to sodium hypochlorite, notably after vigorous chemical decontamination with no hazard either to materials or workers.Lire moins >
Lire la suite >Background Residual contamination by intravenous conventional antineoplastic drugs (ICAD) is still a daily issue in hospital facilities. This study aimed to compare the efficiency (EffQ) of 4 different solutions to remove 23 widely used ICADs from surfaces. Method and findings A solution containing 23 ICADs (4 alkylating agents, 8 antimetabolites, 2 topo-I inhibitors, 6 topo-II inhibitors and 3 spindle poisons) was spread over 100 cm2 stainless steel. After drying, decontamination was carried out using 10×10 cm wipes moistened with 300 μL of one of the following solutions: 70% isopropanol (S1); ethanol-hydrogen peroxide 91.6–50.0 mg/g (S2); 10−2 M sodium dodecyl sulphate/isopropanol 80/20 (S3) or 0.5% sodium hypochlorite (S4). Six tests were performed for each decontamination solution. Two modalities were tested: a single wipe motion from top to bottom or vigorous wiping (n = 6 for each modality). Residual contamination was measured with a validated liquid chromatography with tandem mass spectrometry detection method. Solution efficiency (in %) was computed as follows: EffQ = 1–(quantity after decontamination/quantity before decontamination), as median (min–max) for the 23 ICADs. The overall decontamination efficiency (EffQ) of the 4 solutions was compared by a Kruskall-Wallis test. Decontamination modalities were compared for each solution and per ICAD with a Mann-Whitney test (p<0.05). EffQ were significantly different from one solution to the next for single wipe motion decontamination: 79.9% (69.3–100), 86.5% (13.0–100), 85.4% (56.5–100) and 100% (52.9–100) for S1, S2, S3 and S4 (p<0.0001), respectively. Differences were also significant for vigorous decontamination: EffQ of 84.3% (66.0–100), 92.3% (68.7–100), 99.6% (84.8–100) and 100% (82.9–100) for S1, S2, S3 and S4, respectively (p<0.0001). Generally, vigorous decontamination increased EffQ for all tested solutions and more significantly for the surfactant. Conclusion Decontamination efficiency depended on the solution used but also on the application modality. An SDS admixture seems to be a good alternative to sodium hypochlorite, notably after vigorous chemical decontamination with no hazard either to materials or workers.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
CHU Lille
CHU Lille
Collections :
Date de dépôt :
2023-05-25T03:32:24Z
2024-06-13T12:21:21Z
2024-06-13T12:23:16Z
2024-06-13T12:21:21Z
2024-06-13T12:23:16Z
Fichiers
- document.pdf
- Non spécifié
- Accès libre
- Accéder au document