On the performance of VSI Shewhart control ...
Type de document :
Article dans une revue scientifique: Article original
URL permanente :
Titre :
On the performance of VSI Shewhart control chart for monitoring the coefficient of variation in the presence of measurement errors
Auteur(s) :
Nguyen, Huu Du [Auteur]
Dong-A University
Nguyen, Quoc Thong [Auteur]
Laboratoire de Mathématiques de Bretagne Atlantique [LMBA]
Tran, Kim-Phuc [Auteur]
Génie et Matériaux Textiles [GEMTEX]
Ho, Dang Phuc [Auteur]
Institute of Mathematics
Dong-A University
Nguyen, Quoc Thong [Auteur]
Laboratoire de Mathématiques de Bretagne Atlantique [LMBA]
Tran, Kim-Phuc [Auteur]
Génie et Matériaux Textiles [GEMTEX]
Ho, Dang Phuc [Auteur]
Institute of Mathematics
Titre de la revue :
The International Journal of Advanced Manufacturing Technology
Nom court de la revue :
Int. J. Adv. Manuf. Technol.
Numéro :
104
Pagination :
211-243
Date de publication :
2019-09-21
ISSN :
0268-3768
Mot(s)-clé(s) en anglais :
VSI control chart
Coefficient of variation
Measurement errors
Coefficient of variation
Measurement errors
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
In this paper, we propose a variable sampling interval Shewhart
control chart to monitor the coefficient of variation (CV) squared, denoted by
VSI SH-γ2. The new model overcomes the ARL-biased (average run length)
property ...
Lire la suite >In this paper, we propose a variable sampling interval Shewhart control chart to monitor the coefficient of variation (CV) squared, denoted by VSI SH-γ2. The new model overcomes the ARL-biased (average run length) property of the control chart monitoring the CV in a previous study by design- ing two one-sided charts rather than one two-sided chart. Moreover, the effect of measurement error on the performance of the VSI SH-γ2 control chart is investigated. The incorrect formula for the distribution of the CV in the pres- ence of measurement error in a former study is fixed. Numerical simulations show that the precision errors and accuracy errors do have negative influences on the VSI SH-γ2 chart. An appropriate strategy based on the obtained results is suggested to reduce these negative effects.Lire moins >
Lire la suite >In this paper, we propose a variable sampling interval Shewhart control chart to monitor the coefficient of variation (CV) squared, denoted by VSI SH-γ2. The new model overcomes the ARL-biased (average run length) property of the control chart monitoring the CV in a previous study by design- ing two one-sided charts rather than one two-sided chart. Moreover, the effect of measurement error on the performance of the VSI SH-γ2 control chart is investigated. The incorrect formula for the distribution of the CV in the pres- ence of measurement error in a former study is fixed. Numerical simulations show that the precision errors and accuracy errors do have negative influences on the VSI SH-γ2 chart. An appropriate strategy based on the obtained results is suggested to reduce these negative effects.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
ENSAIT
Junia HEI
ENSAIT
Junia HEI
Collections :
Date de dépôt :
2023-06-20T11:15:27Z
2024-02-20T09:23:17Z
2024-02-29T11:49:03Z
2024-02-20T09:23:17Z
2024-02-29T11:49:03Z
Fichiers
- document
- Accès libre
- Accéder au document