Fetal sheep cerebral electrical activity: ...
Type de document :
Article dans une revue scientifique: Article original
PMID :
URL permanente :
Titre :
Fetal sheep cerebral electrical activity: A new technique to record EEG.
Auteur(s) :
Lacan, Laure [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Ould Hamoud, Yasmine [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Nguyen The Tich, Sylvie [Auteur]
Environnement Périnatal et Santé - EA 4489
De Jonckheere, Julien [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Storme, Laurent [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Debarge, Veronique [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Auvin, Stephane [Auteur]
AP-HP Hôpital universitaire Robert-Debré [Paris]
Sharma, Dyuti [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Garabedian, Charles [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Ghesquière, Louise [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Ould Hamoud, Yasmine [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Nguyen The Tich, Sylvie [Auteur]
![refId](/themes/Mirage2//images/idref.png)
Environnement Périnatal et Santé - EA 4489
De Jonckheere, Julien [Auteur]
![refId](/themes/Mirage2//images/idref.png)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Storme, Laurent [Auteur]
![refId](/themes/Mirage2//images/idref.png)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Debarge, Veronique [Auteur]
![refId](/themes/Mirage2//images/idref.png)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Auvin, Stephane [Auteur]
AP-HP Hôpital universitaire Robert-Debré [Paris]
Sharma, Dyuti [Auteur]
![refId](/themes/Mirage2//images/idref.png)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Garabedian, Charles [Auteur]
![refId](/themes/Mirage2//images/idref.png)
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Ghesquière, Louise [Auteur]
METRICS : Evaluation des technologies de santé et des pratiques médicales - ULR 2694
Titre de la revue :
Journal of Neuroscience Methods
Nom court de la revue :
J. Neurosci. Methods
Pagination :
108888
Date de publication :
2020-08-08
ISSN :
1872-678X
Mot(s)-clé(s) en anglais :
EEG technique
Fetal sheep
Perinatal hypoxia
Fetal sheep
Perinatal hypoxia
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Background
Sheep models are commonly used to study fetal cortical activity, including response to hypoxia. The standard technique consists of recording electrocorticogram (ECOG) in utero using electrodes placed on the ...
Lire la suite >Background Sheep models are commonly used to study fetal cortical activity, including response to hypoxia. The standard technique consists of recording electrocorticogram (ECOG) in utero using electrodes placed on the dura mater. New method We propose a new method for recording the electroencephalogram (EEG) of fetal sheep, using electrodes placed above the skull bone and fixed to the cranial periosteum. Results Twelve animals were instrumented with this new technique. The EEG signal recorded in utero was of sufficient quality for visual and quantitative analysis of the fetal cortical activity. Comparison with existing method This new method is less invasive than the standard method commonly used to record cerebral activity in fetal sheep, because it avoids drilling the skull by hand. The EEG signal recorded in utero had visual and quantitative characteristics comparable to ECOG. Conclusions We present a new method of EEG recording that appears to be an acceptable alternative to the standard ECOG recording method. Fetal sheep EEG can be used to better understand the physiological mechanisms involved in the cerebral response to hypoxia.Lire moins >
Lire la suite >Background Sheep models are commonly used to study fetal cortical activity, including response to hypoxia. The standard technique consists of recording electrocorticogram (ECOG) in utero using electrodes placed on the dura mater. New method We propose a new method for recording the electroencephalogram (EEG) of fetal sheep, using electrodes placed above the skull bone and fixed to the cranial periosteum. Results Twelve animals were instrumented with this new technique. The EEG signal recorded in utero was of sufficient quality for visual and quantitative analysis of the fetal cortical activity. Comparison with existing method This new method is less invasive than the standard method commonly used to record cerebral activity in fetal sheep, because it avoids drilling the skull by hand. The EEG signal recorded in utero had visual and quantitative characteristics comparable to ECOG. Conclusions We present a new method of EEG recording that appears to be an acceptable alternative to the standard ECOG recording method. Fetal sheep EEG can be used to better understand the physiological mechanisms involved in the cerebral response to hypoxia.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
Université de Lille
CHU Lille
CHU Lille
Collections :
Date de dépôt :
2023-11-15T08:23:12Z
2023-12-21T12:43:35Z
2023-12-21T12:43:35Z
Fichiers
- document
- Accès libre
- Accéder au document