Looking through the Eye of the Mouse: A ...
Type de document :
Communication dans un congrès avec actes
DOI :
Titre :
Looking through the Eye of the Mouse: A Simple Method for Measuring End-to-end Latency using an Optical Mouse
Auteur(s) :
Casiez, Géry [Auteur]
Computing tools to empower users [MJOLNIR]
Conversy, Stéphane [Auteur]
ENAC - Equipe Informatique Interactive [LII]
Falce, Matthieu [Auteur]
Computing tools to empower users [MJOLNIR]
Huot, Stephane [Auteur]
Computing tools to empower users [MJOLNIR]
Roussel, Nicolas [Auteur]
Computing tools to empower users [MJOLNIR]
Computing tools to empower users [MJOLNIR]
Conversy, Stéphane [Auteur]
ENAC - Equipe Informatique Interactive [LII]
Falce, Matthieu [Auteur]
Computing tools to empower users [MJOLNIR]
Huot, Stephane [Auteur]
Computing tools to empower users [MJOLNIR]
Roussel, Nicolas [Auteur]
Computing tools to empower users [MJOLNIR]
Éditeur(s) ou directeur(s) scientifique(s) :
ACM Press
Titre de la manifestation scientifique :
UIST '15
Ville :
Charlotte
Pays :
Etats-Unis d'Amérique
Date de début de la manifestation scientifique :
2015-11-08
Titre de la revue :
UIST '15 Proceedings of the 28th Annual ACM Symposium on User Interface Software & Technology
Éditeur :
ACM
Date de publication :
2015-11-11
Mot(s)-clé(s) en anglais :
latency measure
lag
Latency
computer mouse.
latency jitter
lag
Latency
computer mouse.
latency jitter
Discipline(s) HAL :
Informatique [cs]/Interface homme-machine [cs.HC]
Informatique [cs]/Bibliothèque électronique [cs.DL]
Informatique [cs]/Bibliothèque électronique [cs.DL]
Résumé en anglais : [en]
We present a simple method for measuring end-to-end latency in graphical user interfaces. The method works with most optical mice and allows accurate and real time latency measures up to 5 times per second. In addition, ...
Lire la suite >We present a simple method for measuring end-to-end latency in graphical user interfaces. The method works with most optical mice and allows accurate and real time latency measures up to 5 times per second. In addition, the technique allows easy insertion of probes at different places in the system I.e. mouse events listeners - to investigate the sources of latency. After presenting the measurement method and our methodology, we detail the measures we performed on different systems, toolkits and applications. Results show that latency is affected by the operating system and system load. Substantial differences are found between C++/GLUT and C++/Qt or Java/Swing implementations, as well as between web browsers.Lire moins >
Lire la suite >We present a simple method for measuring end-to-end latency in graphical user interfaces. The method works with most optical mice and allows accurate and real time latency measures up to 5 times per second. In addition, the technique allows easy insertion of probes at different places in the system I.e. mouse events listeners - to investigate the sources of latency. After presenting the measurement method and our methodology, we detail the measures we performed on different systems, toolkits and applications. Results show that latency is affected by the operating system and system load. Substantial differences are found between C++/GLUT and C++/Qt or Java/Swing implementations, as well as between web browsers.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Projet ANR :
Collections :
Source :
Fichiers
- https://hal-enac.archives-ouvertes.fr/hal-01226729/document
- Accès libre
- Accéder au document
- https://hal-enac.archives-ouvertes.fr/hal-01226729/document
- Accès libre
- Accéder au document
- https://hal-enac.archives-ouvertes.fr/hal-01226729/document
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- paper.pdf
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- paper.pdf
- Accès libre
- Accéder au document