Modeling and calibration in near-field ...
Type de document :
Compte-rendu et recension critique d'ouvrage
Titre :
Modeling and calibration in near-field microwave microscopy for dielectric constant and loss tangent measurement
Auteur(s) :
Bakli, H. [Auteur]
Haddadi, Kamel [Auteur]
Circuits Systèmes Applications des Micro-ondes - IEMN [CSAM - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Lasri, Tuami [Auteur]
Microtechnology and Instrumentation for Thermal and Electromagnetic Characterization - IEMN [MITEC - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Haddadi, Kamel [Auteur]
Circuits Systèmes Applications des Micro-ondes - IEMN [CSAM - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Lasri, Tuami [Auteur]
Microtechnology and Instrumentation for Thermal and Electromagnetic Characterization - IEMN [MITEC - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Titre de la revue :
IEEE Sensors Journal
Pagination :
4667-4668
Éditeur :
Institute of Electrical and Electronics Engineers
Date de publication :
2016-06-15
ISSN :
1530-437X
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé :
The characterization of liquid samples using evanescent microwave fields is described. A calibration model is developed to relate the measured near-field reflection coefficient to the local properties of the sample under ...
Lire la suite >The characterization of liquid samples using evanescent microwave fields is described. A calibration model is developed to relate the measured near-field reflection coefficient to the local properties of the sample under test. As a demonstration, permittivity extraction of different sodium chloride solutions is experimentally determined. The accuracy of 0.3% and 1.3% is obtained for the dielectric constant and the loss tangent at 2.45 GHz.Lire moins >
Lire la suite >The characterization of liquid samples using evanescent microwave fields is described. A calibration model is developed to relate the measured near-field reflection coefficient to the local properties of the sample under test. As a demonstration, permittivity extraction of different sodium chloride solutions is experimentally determined. The accuracy of 0.3% and 1.3% is obtained for the dielectric constant and the loss tangent at 2.45 GHz.Lire moins >