Enhancement of buildings energy efficiency ...
Document type :
Article dans une revue scientifique
Permalink :
Title :
Enhancement of buildings energy efficiency using passive PCM coupled with natural ventilation in the Moroccan climate zones
Author(s) :
Salihi, Mustapha [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Chhiti, Younes [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
El Fiti, Maryam [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Harmen, Yasser [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Chebak, Ahmed [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Jama, Charafeddine [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Chhiti, Younes [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
El Fiti, Maryam [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Harmen, Yasser [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Université Ibn Tofaïl [UIT]
Chebak, Ahmed [Auteur]
Université Mohammed VI Polytechnique = Mohammed VI Polytechnic University [Ben Guerir] [UM6P]
Jama, Charafeddine [Auteur]
Unité Matériaux et Transformations (UMET) - UMR 8207
Journal title :
Energy and Buildings
Abbreviated title :
Energy and Buildings
Volume number :
315
Pages :
114322
Publisher :
Elsevier BV
Publication date :
2024-07-15
ISSN :
0378-7788
HAL domain(s) :
Chimie/Matériaux
English abstract : [en]
The integration of Phase Change Materials (PCMs) in building envelopes has gained significant attention in recent years as a promising solution for thermal energy storage. PCM technology utilizes the latent heat of a ...
Show more >The integration of Phase Change Materials (PCMs) in building envelopes has gained significant attention in recent years as a promising solution for thermal energy storage. PCM technology utilizes the latent heat of a material to store and release large amounts of energy, making it an effective method for passive thermal regulation and stabilization of the indoor building temperatures. However, to fully exploit the potential of the PCM, it must be completely charged and discharged in each cycle. With this fact in mind, this work aims to assess the performance of the PCMs in Moroccan climate zones, as well as to find out the best combination of PCM and natural ventilation to enhance the overall cooling energy performance of buildings. To this end, a numerical investigation was conducted in a residential building located in six climate regions of Morocco. The EnergyPlus software with the integrated PCM hysteresis model was used. Firstly, the effect of the PCM phase change temperature throughout the year was evaluated considering six cities located in those climates. Subsequently, an analysis was conducted during the summer season, resulting in the identification of the optimal configuration regarding PCM phase change temperature and thickness for each city. Furthermore, various natural ventilation scenarios i.e. night and whole-day natural ventilation, were implemented to investigate their impact on the process of PCM charge–discharge cycle. The results reveal that the integration of natural ventilation in PCM-enhanced building was an effective method that solidifies the PCM every required cycle. The integration of PCM with night natural ventilation (NNV) leads to improve the PCM activation by between 22.4% and 26.1%, in the warm and temperate Mediterranean climate. However, whole-day natural ventilation controlled (NVC) further decreases cooling energy consumption by 2–9% compared to NNV in all studied climates, making it the best combination.Show less >
Show more >The integration of Phase Change Materials (PCMs) in building envelopes has gained significant attention in recent years as a promising solution for thermal energy storage. PCM technology utilizes the latent heat of a material to store and release large amounts of energy, making it an effective method for passive thermal regulation and stabilization of the indoor building temperatures. However, to fully exploit the potential of the PCM, it must be completely charged and discharged in each cycle. With this fact in mind, this work aims to assess the performance of the PCMs in Moroccan climate zones, as well as to find out the best combination of PCM and natural ventilation to enhance the overall cooling energy performance of buildings. To this end, a numerical investigation was conducted in a residential building located in six climate regions of Morocco. The EnergyPlus software with the integrated PCM hysteresis model was used. Firstly, the effect of the PCM phase change temperature throughout the year was evaluated considering six cities located in those climates. Subsequently, an analysis was conducted during the summer season, resulting in the identification of the optimal configuration regarding PCM phase change temperature and thickness for each city. Furthermore, various natural ventilation scenarios i.e. night and whole-day natural ventilation, were implemented to investigate their impact on the process of PCM charge–discharge cycle. The results reveal that the integration of natural ventilation in PCM-enhanced building was an effective method that solidifies the PCM every required cycle. The integration of PCM with night natural ventilation (NNV) leads to improve the PCM activation by between 22.4% and 26.1%, in the warm and temperate Mediterranean climate. However, whole-day natural ventilation controlled (NVC) further decreases cooling energy consumption by 2–9% compared to NNV in all studied climates, making it the best combination.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
CNRS
INRAE
ENSCL
CNRS
INRAE
ENSCL
Collections :
Research team(s) :
Procédés de Recyclage et de Fonctionnalisation (PReF)
Submission date :
2024-09-03T13:33:28Z
2024-09-04T08:29:04Z
2024-09-04T08:29:04Z