Case series of aortic arch disease treated ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
PMID :
URL permanente :
Titre :
Case series of aortic arch disease treated with branched stent-grafts
Auteur(s) :
Clough, Rachel E. [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Spear, Rafaelle [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Van Calster, Katrien [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Azzaoui, Richard [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Sobocinski, Jonathan [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Fabre, Dominique [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Haulon, Stephan [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Spear, Rafaelle [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Van Calster, Katrien [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Hertault, Adrien [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Azzaoui, Richard [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Sobocinski, Jonathan [Auteur]
Médicaments et biomatériaux à libération contrôlée: mécanismes et optimisation - Advanced Drug Delivery Systems - U 1008 [MBLC - ADDS]
Advanced Drug Delivery Systems (ADDS) - U1008
Fabre, Dominique [Auteur]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Haulon, Stephan [Auteur]
Centre Hospitalier Régional Universitaire [CHU Lille] [CHRU Lille]
Pôle des Cardiopathies Congénitales du Nouveau-Né à L'adulte - Centre Constitutif Cardiopathies Congénitales Complexes M3C, Groupe Hospitalier Paris Saint-Joseph, Hôpital Marie-Lannelongue, Inserm U999, Université Paris-Saclay
Titre de la revue :
The British journal of oral surgery
Nom court de la revue :
Br J Surg
Numéro :
105
Pagination :
358-365
Date de publication :
2018-03-01
ISSN :
1365-2168
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Surgical repair of aortic arch pathology is complex and associated with significant morbidity and mortality. Alternative approaches have been developed to reduce these risks, including the use of thoracic stent-grafts with ...
Lire la suite >Surgical repair of aortic arch pathology is complex and associated with significant morbidity and mortality. Alternative approaches have been developed to reduce these risks, including the use of thoracic stent-grafts with fenestrations or in combination with bypass procedures to maintain supra-aortic trunk blood flow. Branched stent-grafts are a novel approach to treat aortic arch pathology. Consecutive patients with aortic arch disease presenting to a single university hospital vascular centre were considered for branched stent-graft repair (October 2010 to January 2017). Patients were assessed in a multidisciplinary setting including a cardiologist, cardiac surgeon and vascular surgeon. All patients were considered prohibitively high risk for standard open surgical repair. The study used reporting standards for endovascular aortic repair and PROCESS (Preferred Reporting of Case Series in Surgery) guidelines. Some 30 patients (25 men) underwent attempted branch stent-graft repair. Mean age was 68 (range 37-84) years. Eighteen patients had chronic aortic dissection, 11 patients had an aneurysm and one had a penetrating ulcer. Fourteen patients had disease in aortic arch zone 0, six in zone 1 and ten in zone 2. Twenty-five patients had undergone previous aortic surgery and 24 required surgical revascularization of the left subclavian artery. Technical success was achieved in 27 of 30 patients. Four patients had an endoleak (type Ia, 1; type II, 3). The in-hospital mortality rate was three of 30. Mean length of follow-up was 12·0 (range 1·0-67·8) months, during which time 12 patients required an aortic-related reintervention. Repair of aortic arch pathology using branched stent-grafting appears feasible. Before widespread adoption of this technology, further studies are required to standardize the technique and identify which patients are most likely to benefit.Lire moins >
Lire la suite >Surgical repair of aortic arch pathology is complex and associated with significant morbidity and mortality. Alternative approaches have been developed to reduce these risks, including the use of thoracic stent-grafts with fenestrations or in combination with bypass procedures to maintain supra-aortic trunk blood flow. Branched stent-grafts are a novel approach to treat aortic arch pathology. Consecutive patients with aortic arch disease presenting to a single university hospital vascular centre were considered for branched stent-graft repair (October 2010 to January 2017). Patients were assessed in a multidisciplinary setting including a cardiologist, cardiac surgeon and vascular surgeon. All patients were considered prohibitively high risk for standard open surgical repair. The study used reporting standards for endovascular aortic repair and PROCESS (Preferred Reporting of Case Series in Surgery) guidelines. Some 30 patients (25 men) underwent attempted branch stent-graft repair. Mean age was 68 (range 37-84) years. Eighteen patients had chronic aortic dissection, 11 patients had an aneurysm and one had a penetrating ulcer. Fourteen patients had disease in aortic arch zone 0, six in zone 1 and ten in zone 2. Twenty-five patients had undergone previous aortic surgery and 24 required surgical revascularization of the left subclavian artery. Technical success was achieved in 27 of 30 patients. Four patients had an endoleak (type Ia, 1; type II, 3). The in-hospital mortality rate was three of 30. Mean length of follow-up was 12·0 (range 1·0-67·8) months, during which time 12 patients required an aortic-related reintervention. Repair of aortic arch pathology using branched stent-grafting appears feasible. Before widespread adoption of this technology, further studies are required to standardize the technique and identify which patients are most likely to benefit.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Collections :
Date de dépôt :
2021-01-20T15:59:01Z
2024-02-23T09:26:43Z
2024-02-23T09:26:43Z