Analysis of plasticizers in PVC medical devices: Performance comparison of eight analytical methods
Author(s) :
Bernard, Lise [Auteur]
Bourdeaux, Daniel [Auteur]
Pereira, Bruno [Auteur]
Azaroual, Nathalie [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Barthelemy, Christine [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Breysse, Colette [Auteur]
Chennell, P [Auteur]
Cueff, Regis [Auteur]
dine, thierry [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Eljezi, T [Auteur]
Feutry, Frederic [Auteur]
GENAY, Stéphanie [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
KAMBIA, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lecoeur, Marie [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Masse, Morgane [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Odou, Pascal [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Radaniel, T [Auteur]
Simon, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Vaccher, Claude [Auteur]
Verlhac, C [Auteur]
Yessad, M [Auteur]
Decaudin, Bertrand [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Sautou, Valerie [Auteur]
Bourdeaux, Daniel [Auteur]
Pereira, Bruno [Auteur]
Azaroual, Nathalie [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Barthelemy, Christine [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Breysse, Colette [Auteur]
Chennell, P [Auteur]
Cueff, Regis [Auteur]
dine, thierry [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Eljezi, T [Auteur]
Feutry, Frederic [Auteur]
GENAY, Stéphanie [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
KAMBIA, Nicolas [Auteur]
Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Lecoeur, Marie [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Masse, Morgane [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Odou, Pascal [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Radaniel, T [Auteur]
Simon, Nicolas [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Vaccher, Claude [Auteur]

Verlhac, C [Auteur]
Yessad, M [Auteur]
Decaudin, Bertrand [Auteur]

Groupe de Recherche sur les formes Injectables et les Technologies Associées - ULR 7365 [GRITA]
Sautou, Valerie [Auteur]
Journal title :
Talanta
Abbreviated title :
Talanta
Volume number :
162
Pages :
604-611
Publication date :
2017
HAL domain(s) :
Sciences du Vivant [q-bio]
English abstract : [en]
A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out ...
Show more >A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC-MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the " blind test " carried out on 10 MD samples.Show less >
Show more >A wide variety of medical devices (MDs) used in hospitals are made of flexible plasticized polyvinylchloride (PVC). Different plasticizers are present in variable amounts in the PVC matrix of the devices and can leach out into the infused solutions and may enter into contact with the patients. The ARMED1 project aims to assess the migration of these plasticizers from medical devices and therefore the level of exposure in patients. For the first task of the project, eight methods were developed to directly detect and quantify the plasticizers in the PVC matrix of the MDs. We compared the overall performances of the analytical methods using standardized and validated criteria in order to provide the scientific community with the guidance and the technical specifications of each method for the intended application. We have shown that routine rapid screening could be performed directly on the MDs using the FTIR technique, with cost-effective analyses. LC techniques may also be used, but with limits and only with individual quantification of the main plasticizers expected in the PVC matrix. GC techniques, especially GC-MS, are both more specific and more sensitive than other techniques. NMR is a robust and specific technique to precisely discriminate all plasticizers in a MD but is limited by its cost and its low ability to detect and quantify plasticizer contamination, e.g. by DEHP. All these results have been confirmed by a real test, called the " blind test " carried out on 10 MD samples.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
CHU Lille
CHU Lille
Collections :
Research team(s) :
Innovation/évaluation des médicaments injectables
Modélisation biopharmaceutique et pharmacocinétique
Innovation/évaluation des dispositifs médicaux de perfusion
Modélisation biopharmaceutique et pharmacocinétique
Innovation/évaluation des dispositifs médicaux de perfusion
Submission date :
2019-02-26T17:07:19Z
2021-05-19T06:57:11Z
2021-05-19T06:57:11Z