Influence of the laser source position on ...
Type de document :
Compte-rendu et recension critique d'ouvrage
Titre :
Influence of the laser source position on the generation of Rayleigh modes in a layer–substrate structure with varying degrees of adhesion
Auteur(s) :
Robin, Martin [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Jenot, Frederic [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Ouaftouch, Mohammadi [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Duquennoy, Marc [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Jenot, Frederic [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Ouaftouch, Mohammadi [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Duquennoy, Marc [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Transduction, Propagation et Imagerie Acoustique - IEMN [TPIA - IEMN]
Titre de la revue :
Ultrasonics
Pagination :
106051
Éditeur :
Elsevier
Date de publication :
2020-03
ISSN :
0041-624X
Mot(s)-clé(s) en anglais :
Adhesion
Laser-Ultrasonics
Non-Destructive Testing
Surface Acoustic Waves
Wigner-Ville distribution
Laser-Ultrasonics
Non-Destructive Testing
Surface Acoustic Waves
Wigner-Ville distribution
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Physique [physics]
Informatique [cs]
Physique [physics]
Informatique [cs]
Résumé en anglais : [en]
Non-Destructive Testing of adhesion using Surface Acoustic Waves (SAW) is an important issue in industrial and academic domains. Indeed, these waves are sensitive to the quality of adhesion at the interface between the ...
Lire la suite >Non-Destructive Testing of adhesion using Surface Acoustic Waves (SAW) is an important issue in industrial and academic domains. Indeed, these waves are sensitive to the quality of adhesion at the interface between the substrate and the layer with a thickness comparable to the acoustic wavelength. Furthermore, their propagation distance allows a large majority of the sample to be tested quickly. Numerous studies have used SAW for the Non-Destructive Testing of adhesion. However, some recurrent experimental difficulties may lead to an incorrect interpretation of the results. This is the case when the layer thickness is non-uniform, for example. To provide a quasi-constant thickness, a PolyEthylene Terephthalate (PET) film was placed directly on the substrate surface without any glue and Laser-Ultrasonics was used to investigate this type of structure. As the film was transparent at the optical wavelength used, it was possible to focus the laser source on the substrate surface through the film. To the best of our knowledge, no paper has been published on the influence of the source position on adhesion testing. In this work, two source positions were investigated.Lire moins >
Lire la suite >Non-Destructive Testing of adhesion using Surface Acoustic Waves (SAW) is an important issue in industrial and academic domains. Indeed, these waves are sensitive to the quality of adhesion at the interface between the substrate and the layer with a thickness comparable to the acoustic wavelength. Furthermore, their propagation distance allows a large majority of the sample to be tested quickly. Numerous studies have used SAW for the Non-Destructive Testing of adhesion. However, some recurrent experimental difficulties may lead to an incorrect interpretation of the results. This is the case when the layer thickness is non-uniform, for example. To provide a quasi-constant thickness, a PolyEthylene Terephthalate (PET) film was placed directly on the substrate surface without any glue and Laser-Ultrasonics was used to investigate this type of structure. As the film was transparent at the optical wavelength used, it was possible to focus the laser source on the substrate surface through the film. To the best of our knowledge, no paper has been published on the influence of the source position on adhesion testing. In this work, two source positions were investigated.Lire moins >
Langue :
Anglais
Vulgarisation :
Non
Source :
Fichiers
- https://hal.archives-ouvertes.fr/hal-03182198/document
- Accès libre
- Accéder au document
- https://hal.archives-ouvertes.fr/hal-03182198/document
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- S0041624X19301325.pdf
- Accès libre
- Accéder au document