Model calculation of the magnetic induction ...
Type de document :
Compte-rendu et recension critique d'ouvrage
Titre :
Model calculation of the magnetic induction generated by magnetic nanoparticles flowing into a microfluidic system. Performance analysis of the detection
Auteur(s) :
Fodil, Kamel [Auteur]
Equipe Electronique - Laboratoire GREYC - UMR6072
Denoual, Matthieu [Auteur]
Equipe Electronique - Laboratoire GREYC - UMR6072
Dolabdjian, Christophe [Auteur]
Equipe Electronique - Laboratoire GREYC - UMR6072
Treizebre, Anthony [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Senez, Vincent [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Equipe Electronique - Laboratoire GREYC - UMR6072
Denoual, Matthieu [Auteur]
Equipe Electronique - Laboratoire GREYC - UMR6072
Dolabdjian, Christophe [Auteur]
Equipe Electronique - Laboratoire GREYC - UMR6072
Treizebre, Anthony [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Senez, Vincent [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Titre de la revue :
IEEE Transactions on Magnetics
Pagination :
1-8
Éditeur :
Institute of Electrical and Electronics Engineers
Date de publication :
2014
ISSN :
0018-9464
Discipline(s) HAL :
Sciences de l'ingénieur [physics]/Electromagnétisme
Résumé en anglais : [en]
This paper presents a mathematical model of the detection of the magnetic nanoparticles (MNPs) flowing into a microchannel. To validate the model, the experimental measurements were performed using a ferrofluid and a giant ...
Lire la suite >This paper presents a mathematical model of the detection of the magnetic nanoparticles (MNPs) flowing into a microchannel. To validate the model, the experimental measurements were performed using a ferrofluid and a giant magneto impedance microwire made up of CoFeSiBNb alloy as a sensor. The good agreement between theory and measurement implies the possibility of using the numerical simulation to analyze the system performance for the MNPs detection. In addition, a model calculation was performed, which evaluates the optimal signal-to-noise ratio of the detection system as a function of its main parameters and according to the magnetic induction induced by the MNPs.Lire moins >
Lire la suite >This paper presents a mathematical model of the detection of the magnetic nanoparticles (MNPs) flowing into a microchannel. To validate the model, the experimental measurements were performed using a ferrofluid and a giant magneto impedance microwire made up of CoFeSiBNb alloy as a sensor. The good agreement between theory and measurement implies the possibility of using the numerical simulation to analyze the system performance for the MNPs detection. In addition, a model calculation was performed, which evaluates the optimal signal-to-noise ratio of the detection system as a function of its main parameters and according to the magnetic induction induced by the MNPs.Lire moins >
Langue :
Anglais
Vulgarisation :
Non
Source :
Fichiers
- https://hal.archives-ouvertes.fr/hal-00980048/document
- Accès libre
- Accéder au document
- https://hal.archives-ouvertes.fr/hal-00980048/document
- Accès libre
- Accéder au document
- https://hal.archives-ouvertes.fr/hal-00980048/document
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- hal-00980048.pdf
- Accès libre
- Accéder au document
- hal-00980048.pdf
- Accès libre
- Accéder au document