Determination of the whole-body absorption ...
Type de document :
Communication dans un congrès avec actes
DOI :
Titre :
Determination of the whole-body absorption cross section of a phantom using RiMAX
Auteur(s) :
Bamba, Aliou [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Department of Information Technology
Joseph, Wout [Auteur]
Department of Information Technology
Tanghe, Emmeric [Auteur]
Department of Information Technology
Martens, Luc [Auteur]
Department of Information Technology
Gaillot, Davy [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Lienard, Martine [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Department of Information Technology
Joseph, Wout [Auteur]
Department of Information Technology
Tanghe, Emmeric [Auteur]
Department of Information Technology
Martens, Luc [Auteur]
Department of Information Technology
Gaillot, Davy [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Lienard, Martine [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Titre de la manifestation scientifique :
IEEE Antennas and Propagation Society International Symposium, AP-S/URSI 2013
Ville :
Orlando, FL
Pays :
Etats-Unis d'Amérique
Date de début de la manifestation scientifique :
2013-07-07
Titre de l’ouvrage :
Proceedings of 2013 IEEE Antennas and Propagation Society International Symposium, AP-S/URSI 2013
Date de publication :
2013
Mot(s)-clé(s) en anglais :
reverberation chamber
reverberation time
diffuse multipath components
maximum-likelihood high-resolution channel parameters estimator
whole-body absorption cross section
reverberation time
diffuse multipath components
maximum-likelihood high-resolution channel parameters estimator
whole-body absorption cross section
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
The reverberation time has been measured in a reverberation chamber for different loads and for a cross polarized transceiver at the frequency of 1.8 GHz. We determine the whole-body absorption cross section of a canonical ...
Lire la suite >The reverberation time has been measured in a reverberation chamber for different loads and for a cross polarized transceiver at the frequency of 1.8 GHz. We determine the whole-body absorption cross section of a canonical phantom using a maximum-likehood high-resolution channel parameters estimator - RiMAX - and good agreement has been obtained with the result from the numerical simulations. The relative error between the simulated values and the RiMAX based measured values is less than 1.3 %.Lire moins >
Lire la suite >The reverberation time has been measured in a reverberation chamber for different loads and for a cross polarized transceiver at the frequency of 1.8 GHz. We determine the whole-body absorption cross section of a canonical phantom using a maximum-likehood high-resolution channel parameters estimator - RiMAX - and good agreement has been obtained with the result from the numerical simulations. The relative error between the simulated values and the RiMAX based measured values is less than 1.3 %.Lire moins >