Quantitative (artifact-free) surface potential measurements using Kelvin force microscopy
Auteur(s) :
Melin, Thierry [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Barbet, Sophie [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Diesinger, Heinrich [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Théron, Didier [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Deresmes, D. [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Barbet, Sophie [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Diesinger, Heinrich [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Théron, Didier [Auteur]

Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Deresmes, D. [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Titre de la revue :
Review of Scientific Instruments
Pagination :
036101-1-3
Éditeur :
American Institute of Physics
Date de publication :
2011
ISSN :
0034-6748
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
The measurement of local surface potentials by Kelvin force microscopy (KFM) can be sensitive to external perturbations which lead to artifacts such as strong dependences of experimental results (typically in a ∼1 V range) ...
Lire la suite >The measurement of local surface potentials by Kelvin force microscopy (KFM) can be sensitive to external perturbations which lead to artifacts such as strong dependences of experimental results (typically in a ∼1 V range) with KFM internal parameters (cantilever excitation frequency and/or the projection phase of the KFM feedback-loop). We analyze and demonstrate a correction of such effects on a KFM implementation in ambient air. Artifact-free KFM measurements, i.e., truly quantitative surface potential measurements, are obtained with a ∼30 mV accuracy.Lire moins >
Lire la suite >The measurement of local surface potentials by Kelvin force microscopy (KFM) can be sensitive to external perturbations which lead to artifacts such as strong dependences of experimental results (typically in a ∼1 V range) with KFM internal parameters (cantilever excitation frequency and/or the projection phase of the KFM feedback-loop). We analyze and demonstrate a correction of such effects on a KFM implementation in ambient air. Artifact-free KFM measurements, i.e., truly quantitative surface potential measurements, are obtained with a ∼30 mV accuracy.Lire moins >